S'abonner

Comparison of feldspathic veneer surface treatments on ceramic bracket SBS, ARI and surface roughness after different debonding/polishing methods: An in vitro study - 20/11/21

Doi : 10.1016/j.ortho.2021.08.006 
Cecília Sued Leão 1, Amanda Cunha Regal de Castro 1, Flavio Mendonça Copello 1, , Carlos Nelson Elias 2, Terumitsu Sekito Junior 3, Eduardo Franzotti Sant’Anna 1,
1 Department of Pediatric Dentistry and Orthodontics, Federal University of Rio de Janeiro, Brazil 
2 Instituto Military de Unguentaria, Rio de Janeiro, Brazil 
3 Department of Prosthesis and Dental Materials, Federal University of Rio de Janeiro, Brazil 

Flavio Mendonça Copello, Department of Pedodontics and Orthodontics, Universidade Federal do Rio de Janeiro, (UFRJ), Avenida Professor Rodolpho Rocco, 325, Ilha do Fundão, 21941-617 Rio de Janeiro, RJ, Brazil.Department of Pedodontics and Orthodontics, Universidade Federal do Rio de Janeiro, (UFRJ)Avenida Professor Rodolpho Rocco, 325, Ilha do FundãoRio de Janeiro, RJ21941-617Brazil⁎⁎Eduardo Franzotti Sant’Anna.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 6
Iconographies 1
Vidéos 0
Autres 0

Summary

Objectives

To analyse, in vitro, surface properties and the shear bond strength after debonding and polishing procedures of ceramic brackets directly bonded to 0.3-0.5-mm thick feldspathic veneers.

Materials and methods

Fifty six feldspathic ceramic veneers samples (0.3 to 0.5-mm thick) were allocated into groups according to veneers surface treatment procedures: (S) glaze layer was retained; (SHF) hydrofluoric (HF) acid etch; (SOXA) Al2O3 sandblasting; and (SB) diamond burs roughening. Specimens were treated with silane Monobond N® and ceramic brackets bonded with Transbond XT®. Shear bonding strength (SBS) was assessed with a universal testing machine and ARI evaluated under a stereomicroscopic coupled to a digital camera. Remaining bonding composite was removed using a porcelain polishing kit and surface roughness assessed with a stylus profilometer.

Results

No statistically significant differences were identified for SBS among the study groups (S, SHF, SOXA and SB) (P>0.05). The majority of the specimens presented ARI scores 3 and 2 (P>0.05). All of the study groups presented increased surface roughness after debonding and polishing procedures (P<0.05), with significant greater values observed in SB group (RaF: 1.27±0.41; RzF: 6.23±1.82), (P<0.05).

Conclusions

Surface treatment with hydrofluoric acid etch, Al2O3 sandblasting and diamond bur did not enhance SBS of orthodontic brackets bonded to ceramic veneers. Ceramic surfaces treated with diamond burs presented significantly increased roughness after adhesive removal.

Le texte complet de cet article est disponible en PDF.

Keywords : Dental Veneers, Ceramic bracket, Shear bond strength, ARI, Surface treatment, Surface roughness


Plan


© 2021  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 19 - N° 4

P. 679-684 - décembre 2021 Retour au numéro
Article précédent Article précédent
  • Evaluation of 3D Face-Scan images obtained by stereophotogrammetry and smartphone camera
  • Burçin Akan, Ender Akan, Ahmet O?uz ?ahan, Mert Kalak
| Article suivant Article suivant
  • In vitro comparison of the tensile strength of elastomeric ligatures exposed to Povidone Iodine 1%, Chlorhexidine 0.02%, and hydrogen peroxide 5%
  • Zahra Ebrahiminik, Mohamad Zanganeh, Behzad Salari, Narges Fadaee, Mostafa Mirshahpanah

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.