S'abonner

Mise au point sur l'athérectomie rotationnelle à haute vitesse par Rotablator en 2021 et données du registre France PCI - 26/11/21

Focus on high speed rotational atherectomy by Rotablator in 2021 and datas from France PCI registry

Doi : 10.1016/j.ancard.2021.10.002 
Dr Gabriel Seret 1, , Dr Matthieu Perier 1, Dr Thierry Corcos 1, Pr Denis Angoulvant 2, Dr Marie Pascale Decomis 3, Dr Pierre Marcollet 4, Dr Nicolas Combaret 5, Dr Stephan Chassaing 6, Dr Christophe Thuaire 7, Dr Matthieu Godin 8, Dr Olivier Fichaux 9, Pr Farzin Beygui 10, Dr Louis Viallard 11, Dr Sofiène Daniel Gafsi 12, Dr P-F. Lesault 13, Pr Éric Durand 14, Dr Emmanuel Boiffard 15, Pr Pascal Motreff 5, Dr Grégoire Rangé 7, Dr Hakim Benamer 16
1 Service de cardiologie, Hôpital Foch, 40 rue Worth, 92150 Suresnes, France 
2 Service de cardiologie, Centre Hospitalo-Universitaire de Tours, 37170 Chambray les Tours, France 
3 Service de cardiologie, Pôle santé Oréliance, 45770 Saran, France 
4 Service de cardiologie, Centre Hospitalier Jacques-Cœur, 18020 Bourges, France 
5 Service de cardiologie, Centre Hospitalo-Universitaire Gabriel-Montpied, 63000 Clermont Ferrand, France 
6 Service de cardiologie, Nouvelle Clinique Tours Plus, 37541 Saint Cyr sur Loire, France 
7 Service de cardiologie, Les Hôpitaux de Chartres, 28630 Le Coudray, France 
8 Service de cardiologie, Clinique Saint-Hilaire, 76000 Rouen, France 
9 Service de cardiologie, Centre Hospitalier Régional d'Orléans, 45100 Orléans, France 
10 Service de cardiologie, Centre Hospitalo-Universitaire de Caen, 14033 Caen, France 
11 Service de cardiologie, Centre Hospitalier Henri-Mondor, 15000 Aurillac, France 
12 Service de cardiologie, Groupe Hospitalier du Havre, 76290 Montivilliers, France 
13 Service de cardiologie, Hôpital Privé de l'Estuaire, 76600 Le Havre, France 
14 Service de cardiologie, Centre Hospitalo-Universitaire de Rouen, 76038 Rouen, France 
15 Service de cardiologie, Centre Hospitalier Départemental de Vendée, 85000 La Roche-Sur-Yon, France 
16 Institut Jacques Cartier, Institut Cardiovasculaire Paris Sud (ICPS) Ramsay Générale de Santé, 6 avenue du Noyer-Lambert, 91300 Massy, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Mise au point dans la fin des années 80, l'athérectomie rotationnelle a suscité beaucoup d'espoir par son principe innovant d'abrasion sélective, permettant une réduction (et non plus simple redistribution) du volume de plaque athéroscléreuse, tout en épargnant les tissus sains. Longtemps boudé pour ses résultats décevants en matière de resténose, le Rotablator s'est finalement réaffirmé dans les années 2000 ; ère de l'avènement des stents actifs, de l'essor de l'angioplastie coronaire et donc de l’émergence de lésions complexes. En effet, le Rotablator a démontré un bénéfice indéniable dans la préparation (avant stenting) des lésions complexes (type C) et calcifiées, avec un taux de succès procédural avoisinant les 95 %. Si ces lésions ne représentent qu'un faible pourcentage d'angioplasties coronaires (2-3 %), elles demeurent une impasse technique de l'angioplastie par ballonnet, érigeant le Rotablator en traitement de choix de ces lésions résistantes. Des données de registre attestent de la sécurité de cette thérapie en vie réelle, avec un taux de complications péri-procédurales et de mortalité intra-hospitalière comparable à l'angioplastie conventionnelle (registre France PCI). Toutefois, certaines complications spécifiques, rares mais graves (blocage de fraise, rupture de guide, perforation coronaire), justifient des équipes entrainées, une connaissance parfaite du matériel et un respect rigoureux des bonnes pratiques. En 2018, l'essor concurrentiel d'une nouvelle technique d'athérectomie par lithotripsie intravasculaire (Shockwave) a coïncidé avec un début de diminution d'activité du Rotablator (constatation biaisée par une baisse générale d'activité générée par la pandémie Covid). Cet enrichissement de gamme thérapeutique révolutionne le traitement des lésions calcifiées, tendant vers un ciblage fin des indications, fonction notamment de l'anatomie de distribution du calcium dans la plaque.

Le texte complet de cet article est disponible en PDF.

ABSTRACT

Developed in the late 1980s, rotational atherectomy has raised a lot of hope for its innovative principle of selective ablation, allowing volume reduction (instead of redistribution) of atherosclerotic plaque, while sparing healthy tissue. Long shunned for its disappointing results on restenosis, the Rotablator finally reasserted itself in the 2000s; era of drug eluting stents and coronary angioplasty boom, thus generating emergence of complex lesions. Indeed, the Rotablator has demonstrated an undeniable benefit in complex (type C) and calcified lesions preparation (before stenting), with a procedural success rate of 95%. Although these lesions only represent a small amount (2-3%) of percutaneous coronary interventions (PCI), they remain a technical impasse for plain-old balloon angioplasty strategy, making the Rotablator more suitable for these resistant lesions’ treatment. Registry data attest the safety of this therapy, with a rate of peri-procedural complications and in-hospital mortality comparable to conventional angioplasty (France PCI register). However, certain specific, rare but serious complications (burr entrapment, broken Rotawire, coronary perforation) justify trained teams, perfect knowledge of the equipment, and strict compliance with good practice guidelines. In 2018, the rise of a new method of atherectomy by intra-vascular lithotripsy (Shockwave) has coincided with Rotablator decreasing activity (this finding being biased by a general decrease in PCI activity due to Covid pandemic). This therapeutic range's enhancement revolutionizes calcified lesions treatment, tending towards precise targeting of each indication, depending in particular on calcium distribution's anatomy in the plaque.

Le texte complet de cet article est disponible en PDF.

Mots clés : athérectomie rotationnelle, Rotablator, lésion calcifiée

Keywords : rotational atherectomy, Rotablator, calcified lesion


Plan


© 2021  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 70 - N° 6

P. 435-445 - décembre 2021 Retour au numéro
Article précédent Article précédent
  • Pourquoi et comment j'utilise l'athérectomie orbitale ?
  • Angela Acheampong, Jacques Monsegu
| Article suivant Article suivant
  • Comparative performance of intravenous and intracoronary ergonovine provocation in vasospastic angina
  • Nathan El Bèze, Vincent Millien, Thierry Lefèvre, Bernard Chevalier, Philippe Garot, Thomas Hovasse, Thierry Unterseeh, Stéphane Champagne, Francesca Sanguineti, Antoinette Neylon, Hakim Benamer

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.