S'abonner

Évaluation des bénéfices potentiels liés à l’utilisation d’un brouillard d’eau basse pression dans la lutte contre les incendies chez les sapeurs-pompiers de Paris, à partir d’une évaluation quantitative des risques - 28/11/21

Evaluating the potential benefits of the use of water-mist system in fire fighting operations for Paris firefighters, through quantitative risk assessment

Doi : 10.1016/j.admp.2021.07.007 
J. Dirand a, , F. Rieunier c, F. Testa a, L. Temime b
a aBrigade de sapeurs-pompiers de Paris, 1, place Jules-Renard, 75017 Paris, France 
b Laboratoire MESuRS, Conservatoire National des Arts et Métiers, 292, rue Saint-Martin, 75003 Paris, France 
c Laboratoire Central de la Préfecture de Paris, 39 bis, rue de Dantzig, 75015 Paris, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 13
Iconographies 5
Vidéos 0
Autres 0

Résumé

Objectifs

L’évolution de la conception des bâtiments d’habitation et l’utilisation de nouveaux matériaux introduisent de nouveaux risques pour les sapeurs-pompiers, dont une toxicité des fumées accrue. L’utilisation d’un brouillard d’eau produit par fragmentation hydropneumatique pour lutter contre l’incendie pourrait réduire l’exposition à ces fumées. L’objectif de cette étude est d’évaluer les bénéfices sanitaires potentiels pour les sapeurs-pompiers d’un tel brouillard d’eau sur l’exposition aux fumées au cours de la phase « post-extinction » (dédiée aux opérations de déblai).

Méthodes

Les différents polluants présents au cours de la phase « post-extinction » ont été identifiés et leurs concentrations mesurées dans un cadre expérimental. Ensuite, le temps d’exposition professionnelle des sapeurs-pompiers à ces polluants a été estimé à travers une matrice d’exposition. Enfin, une approche d’évaluation quantitative des risques sanitaires a permis de comparer les risques liés à l’exposition aux fumées dans le cadre d’une attaque classique à ceux liés à l’utilisation d’un brouillard d’eau.

Résultats

Avec l’emploi de moyens d’extinction traditionnels, notre étude met en évidence un risque de cancer en excès montant jusqu’à 1,3/100 000 en fonction du grade des sapeurs-pompiers étudiés, ainsi que des quotients de danger largement supérieurs à 1 pour les effets non cancérigènes. Le brouillard d’eau a un effet protecteur, permettant notamment de réduire l’excès de risque de cancer en-dessous de 2,6/1 000 000. Cependant, malgré l’usage de ce nouveau moyen d’extinction, le niveau de risque hors cancer demeure élevé pour certaines substances toxiques.

Conclusions

Il est nécessaire de mettre en place des actions de prévention afin de diminuer l’exposition aux fumées d’incendie des sapeurs-pompiers et ses impacts sanitaires. Cette étude montre que l’emploi de nouveaux moyens d’extinction tels que la brumisation est une piste intéressante.

Le texte complet de cet article est disponible en PDF.

Summary

Objectives

Changes in residential building design and the use of new construction materials are introducing new risks to firefighters, including increased smoke toxicity. A water-mist system produced by hydropneumatic fragmentation in firefighting operations could reduce the exposure to toxic smoke. The purpose of this study is to assess the potential health benefits for firefighters of such a water-mist system on smoke exposure during the post-extinction phase (dedicated to excavating operations).

Methods

The different pollutants present during the post-extinction phase were identified and their concentrations measured in an experimental context. Then we estimated the duration of occupational exposure of firefighters to these pollutants through an exposure matrix. Finally, using a quantitative health risk assessment approach, we compared the risks associated with smoke exposure in the context of a conventional attack with those associated with the use of a water-mist system.

Results

With the use of traditional firefighting equipment, our study shows an excess cancer risk of up to 1,3/100,000 depending on the rank of the firefighters studied, as well as hazard quotients well above 1 for non-cancer effects. The use of a water-mist fire-fighting system allows to reduce the excess risk of cancer to below 2,6/1,000,000. However, despite the use of this new extinction method, the non-cancer risk level remains high for some toxic substances.

Conclusions

It is necessary to implement preventive actions to reduce the exposure of firefighters to toxic smokes and its health impact. This study shows that innovative firefighting approaches, such as a water-mist firefighting system, could lead to positive results.

Le texte complet de cet article est disponible en PDF.

Mots clés : Pompiers, Brumisation, Brouillard d’eau, Fumées d’incendie, Excès de risque, Quotient de danger, Évaluation quantitative des risques sanitaires

Keywords : Water-mist firefighting system, Smoke fire, Excess risk, Risk quotient, Quantitative assessment of sanitary risks


Plan


© 2021  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 82 - N° 6

P. 601-613 - novembre 2021 Retour au numéro
Article précédent Article précédent
  • Dépistage participatif des risques professionnels chez les vendeuses exerçant aux abords des axes routiers du marché Dantokpa à Cotonou, Bénin
  • H.A. Gbègnidé, G.E. Sopoh, D.A. Davou, B. Fayomi, M. Makoutodé, G. Agodokpessi
| Article suivant Article suivant
  • Le maintien en emploi dans la nouvelle Loi pour renforcer la prévention en santé au travail de 2021 : une ambition renouvelée
  • S. Fantoni Quinton

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.