S'abonner

Vertebral augmentation via the rib approach: surgical essentials and therapeutic effects - 14/01/22

Doi : 10.1016/j.neuchi.2022.01.001 
Yanping Ding 1, Jinhai Liu 2, Xiaofei Han 3, Ying Yang 1, , Qu-dong Yin 3,
1 Department of Radiology, Wuxi No. 9 People’s Hospital Affiliated to Soochow University, Wuxi 214062, Jiangsu, China 
2 Department of Orthopaedics, Wuwei People’s Hospital, Wuwei 733000, Ganxu, China 
3 Department of Orthopaedics, Wuxi No. 9 People’s Hospital Affiliated to Soochow University, Wuxi 214062, Jiangsu, China 

Corresponding author: Department of Radiology, Department of Orthopaedics. Wuxi No. 9 People’s Hospital Affiliated to Soochow University, No. 999 Liangxi Road, Wuxi 214062, Jiangsu, ChinaDepartment of Radiology, Department of Orthopaedics. Wuxi No. 9 People’s Hospital Affiliated to Soochow UniversityNo. 999 Liangxi RoadWuxiJiangsu214062China
Sous presse. Manuscrit accepté. Disponible en ligne depuis le Friday 14 January 2022
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Objective.-The rib approach is a new extrapedicular approach for vertebral augmentation in the thoracic spine. This article discusses the surgical essentials and therapeutic effect.

Methods.-Computed tomography (CT) imagings were obtained from 100 subjects to stimulate a Φ 4-mm puncture needle via the rib approach to determine the anatomical parameters of the channel and the position of the needle inserted in the vertebral body. Application results for 26 patients with T5-10 lesions were observed, four patients were treated under general anesthesia and 22 were treated under local anesthesia.

Results.-The channel diameter was 5.9-7.0 mm. In T5-10, the puncture needle could reach the middle of the midsagittal line of vertebral bodies in the transverse plane and only reached the middle and upper parts of the vertebral body in the sagittal plane. One week after surgery, the visual analog scale (VAS) sores decreased to 2.4 ± 0.8, the ODI decreased to 13.4 ± 5.9, and the anterior and posterior vertebral body height ratios recovered to 82.2 ± 13.7% and 86.3 ± 13.2%, respectively (all, P < 0.05). No intraspinal cement leakage or nerve injury was noted.

Conclusions.-Vertebral augmentation via the rib approach is suitable only for patients with T5-10 lesions located in the middle and upper parts of the vertebral body. The puncture needle should be inclined inward and downward. This method is characterized by simple execution and low risks of intraspinal cement leakage and nerve injury.

Le texte complet de cet article est disponible en PDF.

Keywords : Thoracic vertebrae, Vertebral augmentation, Via the rib approach, Indication, Effect



© 2022  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.