Microcatheter movement in the aneurysm due to low-profile visualized intraluminal support deployment: An in vitro study - 09/04/22

Doi : 10.1016/j.neurad.2022.03.010 
Hiroyuki Ikeda , Masanori Kinosada, Minami Uezato, Yoshitaka Kurosaki, Masaki Chin, Sen Yamagata
 Department of Neurosurgery, Kurashiki Central Hospital, Kurashiki, Japan 

Corresponding author: Department of Neurosurgery, Kurashiki Central Hospital, 1-1-1 Miwa, Kurashiki, 710-8602, Japan.Department of NeurosurgeryKurashiki Central Hospital1-1-1 MiwaKurashiki710-8602Japan
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Saturday 09 April 2022
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background

When a microcatheter is in the aneurysm, it may move due to low-profile visualized intraluminal support (LVIS) deployment. This study was designed to determine this mechanism.

Methods

Six silicon aneurysm models were created by combining the aneurysm location (side wall or bifurcation) and the parent vessel configuration (straight, ipsilateral bending, or contralateral bending). After adjusting the microcatheter tip position in the aneurysm by pushing or pulling, an LVIS stent was deployed to cover the aneurysm neck, and the changes in the microcatheter tip position was measured. Pushing and pulling were performed 15 times each for each model, for a total of 180 experiments.

Results

In all experiments, the microcatheter tip moved with LVIS deployment. The total movement distance was 3.00±1.59 mm, which was significantly different between the push and pull groups (p = 0.049), between the three side-wall aneurysm models (p<0.0001), and between the three bifurcation aneurysm models (p<0.0001). Backward movement in the aneurysm occurred in 21% (37/180). The frequency of backward movement was significantly different between the side-wall and bifurcation aneurysm models (p = 0.0265) and between the push and pull groups (p<0.0001). The forward movement distance was significantly different between the side-wall (n = 78) and bifurcation (n = 65) aneurysm models (p<0.0001).

Conclusions

The aneurysm location, the parent vessel configuration, and adjustment of the microcatheter tip position by pushing or pulling may affect the total movement distance and forward/backward movement of the microcatheter tip due to LVIS deployment.

Le texte complet de cet article est disponible en PDF.

Graphical abstract




Image, graphical abstract

Le texte complet de cet article est disponible en PDF.

Highlights

We examine microcatheter movement in the aneurysm due to LVIS deployment.
An aneurysm location (side wall or bifurcation) affects microcatheter movement.
A parent vessel configuration (straight, ipsilateral bending, or contralateral bending) affects microcatheter movement.
An adjustment of the microcatheter tip position by pushing or pulling affects microcatheter movement.

Le texte complet de cet article est disponible en PDF.

Keywords : Aneurysm, Device, Stent, LVIS, Microcatheter, Jailing technique

Abbreviations : LVIS


Plan


© 2022  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.