S'abonner

Automated Digitization of the Cardiotocography Signals from Real Scene Image of Binary Clinic Report - 24/05/22

Doi : 10.1016/j.irbm.2022.02.001 
Y. Zhang a, Y. Si a, Z. Liu a, Z. Zhao a, , H. Ye b, ⁎⁎
a School of Electronics and Information, Hangzhou Dianzi University, Hangzhou, PR China 
b Department of Obstetrics, Woman's Hospital, School of Medicine, Zhejiang University, Hangzhou, PR China 

Corresponding author at: School of Electronics and Information, Hangzhou Dianzi University, Hangzhou, 310000, PR China.School of Electronics and InformationHangzhou Dianzi UniversityHangzhou310000PR China⁎⁎Corresponding author at: Department of Obstetrics, Woman's Hospital, School of Medicine, Zhejiang University, Hangzhou, 310000, PR China.Department of ObstetricsWoman's HospitalSchool of MedicineZhejiang UniversityHangzhou310000PR China

Graphical abstract

Le texte complet de cet article est disponible en PDF.

Abstract

Objective

Cardiotocography (CTG) is a popular clinical tool to assess foetal health status. Automatic CTG analysis can remove the judgement differences of inter- and intra- doctors. However, absence of CTG database has hindered the development of automatic CTG analysis based on deep learning. Therefore, digitization of CTG signal from clinic report is an important way to enrich CTG database, and in turn promote the automatic CTG analysis.

Method

The proposed digitization method extracts digital signal from the commonly used binary CTG paper reports. An adaptive region positioning algorithm based on statistical calculation is used to locate signal regions. Then, by deducing the dynamic minimal weight sum in theory, methods based on statistical calculation and on the weight sum are designed to remove grid lines. Next, according to different breakpoint types and signal line trends, different signal reconstruction methods are formulated. This realize extracting the signal line from binary background grid lines. Finally, a calibration method based on segmented sampling is designed to reduce calibration error due to smartphone lens distortion.

Results

The experimental results show that the correlation coefficients of FHR and UC of proposed method both reached 0.98. After three expert gynaecologists's evaluations, there are no clinically relevant differences were identified between the extracted signals and the reference ones.

Le texte complet de cet article est disponible en PDF.

Highlights

First time to extract the cardiotocograph signals from the binary clinic paper report.
Adaptive region positioning algorithm based on statistical calculation.
Statistical calculation and weight sum are designed to remove grid lines.
Segmented sampling is designed to reduce calibration error due to smartphone lens distortion.
Digitization of CTG signal is important way to promote the automatic CTG analysis.

Le texte complet de cet article est disponible en PDF.

Keywords : Signal extraction, Digitization, Binary CTG paper reports, Real scene image


Plan


© 2022  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 43 - N° 3

P. 143-150 - juin 2022 Retour au numéro
Article précédent Article précédent
  • Editorial Board
| Article suivant Article suivant
  • Distributed Biomedical Scheme for Controlled Recovery of Medical Encrypted Images
  • D. Pandey, U. Rawat, N.K. Rathore, K. Pandey, P.K. Shukla

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.