Implantation du dispositif XEN 45® dans la chirurgie du glaucome : étude bicentrique bispective s’intéressant au glaucome cortisonique par rapport au glaucome primitif à angle ouvert - 27/07/22

XEN 45® gel stent implantation in glaucoma surgery: Dual-center comparative study between steroid-induced glaucoma and primary open angle glaucoma

Doi : 10.1016/j.jfo.2022.04.007 
C. Cornée , I. Orignac, M. Wargny, M. Clément, C. Varnier, G. Le Meur, P. Lebranchu, M. Weber
 Service d’ophtalmologie, centre hospitalo-universitaire de Nantes, 1, place Alexis-Ricordeau, 44000 Nantes, France 

Auteur correspondant. Service consultations d’ophtalmologie, 6e étage Nord, centre hospitalo-universitaire de Nantes, 1, place Alexis-Ricordeau, 44000 Nantes, France.Service consultations d’ophtalmologie, 6e étage Nord, centre hospitalo-universitaire de Nantes1, place Alexis-RicordeauNantes44000France
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Wednesday 27 July 2022
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Résumé

Introduction

Le XEN 45® gel stent est un dispositif de drainage ab interno de l’humeur aqueuse indiqué en cas de glaucome modéré avec échec des traitements médicaux. Son efficacité a été démontrée dans le glaucome primitif à angle ouvert (GPAO). Toutefois, la littérature est limitée en ce qui concerne les glaucomes secondaires, notamment le glaucome cortisonique (GC), défini comme une neuropathie optique induite par l’utilisation de corticoïdes locaux ou systémiques sans majoration du flare.

Matériels et méthodes

Nous avons réalisé une étude de cohorte bicentrique bispective entre avril 2019 et janvier 2021. Elle portait sur 66 yeux opérés, répartis en deux groupes : GPAO (56 yeux) et GC (10 yeux). Le critère de jugement principal était la réduction relative de la pression intraoculaire (PIO) à trois mois de la chirurgie dans le groupe GC. Trois issues étaient définies : succès total, succès partiel et échec.

Résultats

Le taux de succès total était de 100 % dans le groupe GC et de 42,6 % dans le groupe GPAO. La PIO préopératoire était respectivement de 36,1±9,1mmHg et de 19,0±7,3mmHg. La réduction de la PIO était de 69,1±11,7 % dans le groupe GC et de 21,8±30,3 % dans le groupe GPAO. Les patients étaient d’âge inférieur dans le groupe GC (49,3±21,2 versus 71,1±8,4 ans) et la préparation conjonctivale préopératoire était plus longue dans ce même groupe (12 versus 5 semaines). Le taux de needling était de 17,9 % dans le groupe GPAO et de 10 % dans le groupe GC.

Conclusion

L’implant XEN 45® est efficace dans le traitement des glaucomes cortisoniques. D’autres études seront nécessaires pour préciser les facteurs prédictifs de succès de la procédure et définir un profil de bon candidat.

Le texte complet de cet article est disponible en PDF.

Summary

Introduction

XEN 45® gel stent is an ab interno aqueous humor drainage device indicated for moderate glaucoma refractory to medical management. Its efficacy has been demonstrated in primary open-angle glaucoma (POAG). However, there are few studies on secondary glaucoma, including steroid-induced glaucoma (CG), defined as optic neuropathy induced by using local or systemic corticosteroids without increased flare.

Methods

We conducted a dual-center comparative cohort study between April 2019 and January 2021. 66 operated eyes were included, divided into two groups: POAG (56 eyes) and GC (10 eyes). The primary endpoint was the relative reduction in intraocular pressure (IOP) at three months postoperatively in the GC group. Three outcomes were defined: total success, partial success and failure.

Results

The total success rate was 100% in the GC group and 42.6% in the POAG group. Preoperative IOP was 36.1±9.1mmHg and 19.0±7.3mmHg respectively. IOP reduction was 69.1±11.7% in the GC group and 21.8±30.3% in the POAG group. Patients were younger in the GC group (49.3±21.2 versus 71.1±8.4 years), and preoperative conjunctival preparation was longer in this group (12 versus 5 weeks). The needling rate was 17.9% in the POAG group and 10% in the GC group.

Conclusion

The XEN 45® gel stent is effective in the treatment of steroid-induced glaucoma. Further studies will be required to identify predictive factors for success and to establish criteria for good candidacy.

Le texte complet de cet article est disponible en PDF.

Mots clés : XEN 45® gel stent, Pression intraoculaire, Glaucome cortisonique, Glaucome primitif à angle ouvert, Minimally Invasive Glaucoma Surgery, Chirurgie filtrante, Needling, Uvéite

Keywords : XEN 45® gel stent, Intraocular pressure, Steroid-induced glaucoma, Primary open angle glaucoma, Minimally Invasive Glaucoma Surgery, Filtering surgery, Needling, Uveitis


Plan


© 2022  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.