S'abonner

Comparison of the shear bond strength between metal brackets and Transbond™ XT, Filtek™ Z250 and Filtek™ Z350 before and after gastroesophageal reflux: An in vitro study - 07/08/22

Doi : 10.1016/j.ortho.2022.100664 
Ana Lucia Silva 1, Ana Paula Terossi de Godoi 1, Analia Gabriella Borges Ferraz Facury 2, José Guilherme Neves 2, Américo Bortolazzo Correr 2, Lourenço Correr-Sobrinho 2, Ana Rosa Costa 1,
1 Department of Orthodontics, University Center of the Hermínio Ormetto Foundation – FHO, Araras, SP, Brazil 
2 Department of Restorative Dentistry, Dental materials area, Piracicaba Dental School, State University of Campinas, FOP–UNICAMP, Piracicaba, SP, Brazil 

Ana Rosa Costa, Department of Orthodontics, University Center of the Hermínio Ormetto Foundation – FHO,, Maximiliano-Baruto Avenue, 500, 13607-339 Araras, Sao Paulo, Brazil.Department of Orthodontics, University Center of the Hermínio Ormetto Foundation – FHO,Maximiliano-Baruto Avenue, 500Araras, Sao Paulo13607-339Brazil

Summary

Purpose

To evaluate in vitro the effect of gastroesophageal reflux, before and after bonding of metal brackets on composite resin surface.

Materials and methods

Two hundred and ten resin discs were divided into 5 groups (n=42), according to the time and medium of storage: 24h, 7- and -30 days in artificial saliva (AS) and hydrochloric acid (HCL). Twelve samples from each group were submitted to surface roughness analysis (n=60). The other one hundred and fifty samples were divided into 3 groups (n=50) according to the bonding material: Transbond™ XT (TXT), 3M™ Filtek™ Z250 (Z250) and 3M™ Filtek™ Z350 XT (Z350). After bonding, the samples were subdivided, one more time, into 5 groups (n=10) according to the time (24h, 7, and 30 days) and medium storage (AS, HCL). Following, the shear bond strength (SBS) analysis was accomplished. Erosive challenge was performed for 7 or 30 days, before and after bonding of orthodontic brackets, for 1min, 4 times a day. SBS was performed in a universal testing machine (Instron) at 0.5mm/min. SBS data were subjected to two-way ANOVA and Tukey's test (α=0.05).

Results

TXT showed higher SBS values in all conditions (AS – 10.9±2.0 (24h); 10.5±4.9 (7 days); 9.4±2.2 (30 days); HCL – 11.5±3.7 (7 days); 8.0±2.1 (30 days)) – (P<0.0001). No statistical difference was detected in SBS between Z250 and Z350 composite resins (Z250 SBS: AS – 7.1±1.9 (24h), 5.2±1.8 (7 days), 4.5±1.5 (30 days); HCL – 5.2±2.3 (7 days), 5.0±2.5 (30 days)) – (P<=0.063)/Z350 SBS: AS - 7.4±1.0 (24h); 3.7±1.7 (7 days); 3.4±1.7 (30 days); HCL – 3.5±3.3 (7 days); 4.4±1.2 (30 days)) – (P<=0.167), respectively). Storage times and media did not statistically influence the SBS of TXT and Z250 composite resins (P>0.05), but did influence the Z350 SBS (P<0.05).

Conclusion

Regardless of time and storage medium, TXT was the best composite resin for bonding brackets. Furthermore, the erosive challenge did not lead to surface changes in the Z250 resin at 7 and 30 days, unlike the Z350 resin.

Le texte complet de cet article est disponible en PDF.

Keywords : Gastroesophageal reflux, Orthodontic brackets, Composite resins, Hydrochloric acid, Dental bonding, Shear strength


Plan


© 2022  CEO. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 20 - N° 3

Article 100664- septembre 2022 Retour au numéro
Article précédent Article précédent
  • Evaluation and comparison of stresses and displacements generated by four different types of asymmetric maxillary expansion appliances in true unilateral crossbite using finite element method
  • Tamanna Hoque, Dilip Srinivasan, Sushil Chakravarthi, Ravi Kannan
| Article suivant Article suivant
  • Comparative effects of tungsten, diamond burs and laser for residual adhesive removal after orthodontic debonding on flexural strength, surface roughness and phase transformation of high-translucent zirconia: An in vitro study
  • Yasamin Babaee Hemmati, Hamid Neshandar Asil, Mehran Falahchai, Nika Safari

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.