S'abonner

A prospective observational study to compare transfusion outcomes in ABO identical versus ABO non-identical single donor platelet concentrates: An experience from a tertiary healthcare center in India - 18/08/22

Doi : 10.1016/j.tracli.2022.05.001 
Prashant Pandey , Supriya Kumari, Saikat Mandal, Divya Setya, Praveen Kumar
 Transfusion Medicine & Blood centre, Jaypee Hospital, Noida, Delhi NCR, India 

Corresponding author at: Transfusion Medicine & Blood centre, Jaypee Hospital, Noida, Delhi NCR, India.Transfusion Medicine & Blood centre, Jaypee HospitalNoida, Delhi NCRIndia

Abstract

ABO incompatible single donor platelet concentrates (SDPC) have a concern about unsatisfactory increments as well as possibility of hemolytic transfusion reaction. But from Indian population no study has commented on the clinical and laboratory outcome of ABO mismatched platelet transfusion. The aim of study was to compare transfusion outcomes in ABO identical versus ABO non-identical single donor platelet concentrates. In this prospective observational study, 400 SDPC transfusions among different patients were included. In group A (n=200), ABO identical SDPC transfusions and in group B (n=200) ABO non-identical SDPC transfusions were added. Corrective count increment (CCI), absolute count increment (ACI), percent platelet recovery (PPR) were calculated and incidents of hemolytic transfusion reactions were noted. In group A mean±SD of ACI, CCI and PPR were as 30.78±12.51, 15.10±6.677, 39,948.9±20,099.392. In group B, mean±SD of ACI, CCI and PPR were – 25.4±15.65, 12.509±5.906, 33,559.2±22,150.304. And when CCI, ACI, PPR were compared with group A and group B, statistically significant differences were noted (P<0.05). There was statistically significant difference in CCI, ACI and PPR in oncology patients and other prophylactic recipients except patients with dengue and other infectious disease. But there was no hemolytic transfusion reaction noted in any group. Our study clearly establish the potential benefits of ABO-identical PLT transfusion. It also points out that in emergency conditions or when there is a paucity in inventory, ABO non-identical SDPC transfusion may be lifesaving and clinically significant.

Le texte complet de cet article est disponible en PDF.

Keywords : ABO identical SDPC, Platelet


Plan


© 2022  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 29 - N° 3

P. 213-218 - août 2022 Retour au numéro
Article précédent Article précédent
  • An audit to estimate the quality of practices followed during bedside blood transfusion in a tertiary care hospital and role of continuous medical education in it
  • Ishita Kathuria, Saikat Mandal, Shovika Negi, Ranjan Kumar, Deepika Parwan, Vibhu Ranjan Gupta, Saurabh Gahlote
| Article suivant Article suivant
  • Reverse algorithm for screening of syphilis and trends in prevalence among blood donors in Coastal Karnataka
  • S. Sangthang, M. Raturi, D. Kandsamy, D. Chenna, G. Mohan, S. Shastry

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.