The impact of a closed-loop electronic blood transfusion system on transfusion errors and staff time in a children's hospital - 18/08/22

Doi : 10.1016/j.tracli.2022.03.004 
Yu Shi a, 1, Chengjie Ye b, 1, Hongsheng Wang c, Di Cao a, Meixiu Liu d, Jin Xu d, Ronghua Yang a, Lingzhi Shen b, Gongbao Liu a, Xiaowen Zhai c,
a Division of Medical Administration National Children's Medical Center Children's Hospital of Fudan University, Shanghai, China 
b Information Technology center National Children's Medical Center Children's Hospital of Fudan University, Shanghai, China 
c Department of Hematology National Children's Medical Center Children's Hospital of Fudan University, Shanghai, China 
d Department of Clinical Laboratory National Children's Medical Center Children's Hospital of Fudan University, Shanghai, China 

Corresponding author.

Abstract

Objectives

To assess the impact of a closed-loop electronic blood transfusion system on transfusion errors and staff time.

Materials and methods

Before and after study in all wards of a children's hospital, involving patients and staff of all the wards. The changes were closed-loop electronic blood transfusion, barcode patient identification, electronic blood transfusion administration records and error pop-up warning. The main outcome measures were percentage of blood transfusion errors, time spent on transfusion tasks.

Results

Transfusion errors were identified in 3.87% of 2556 blood transfusion orders pre-intervention and 0.78% of 2577 orders afterwards (P<0.01). Phlebotomists, nurses, and physicians may make mistakes, including wrong blood type when apply for blood, wrong patient when blood draw or transfusion, wrong dose when apply for blood and the wrong tube label when blood draw or cross-matching, which are significantly reduced after change (1.09% vs 0.31%, 1.13% vs 0%, 0.31% vs 0%, 1.33% vs.0.78%, P<0.01). Time spent on blood apply was 5.3±1.2min, hand over blood bag at the transfusion department was 14.9±1.4min and blood transfusion was 15.8±2.4min. Time per transfusion round decreased to 2.6±1.0min, 6.3±1.6min and 9.3±2.2min respectively (P<0.01).

Conclusions

A closed-loop electronic blood transfusion, barcode patient identification and error pop-up warning reduced transfusion errors, and increased confirmation of patient and blood types identity before transfusion. Time spent on blood transfusion tasks reduced.

Le texte complet de cet article est disponible en PDF.

Keywords : Patient safety, Blood transfusion, Closed-loop electronic blood transfusion system


Plan


© 2022  Société française de transfusion sanguine (SFTS). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 29 - N° 3

P. 250-252 - août 2022 Retour au numéro
Article précédent Article précédent
  • Adverse reactions following transfusion of blood components, with a focus on some rare reactions: Reports to the International Haemovigilance Network Database (ISTARE) in 2012–2016
  • C. Politis, J. Wiersum-Osselton, C. Richardson, E. Grouzi, I. Sandid, G. Marano, N. Goto, J. Condeço, K. Boudjedir, M. Asariotou, L. Politi, K. Land
| Article suivant Article suivant
  • Positive direct antiglobulin tests in cancer patients hospitalized with COVID-19: A brief report from India
  • S.S. Datta, S. Basu, D. Basu, M. Reddy, S. Chatterji

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.