S'abonner

Impact du nouveau règlement européen 2017/745 relatif aux dispositifs médicaux sur l’activité des pharmacies hospitalières : exemple de la fonction d’approvisionnement pharmaceutique au sein d’un centre hospitalo-universitaire français - 19/08/22

Impact of the new European regulation 2017/745 on medical devices on hospital pharmacies activity: Example on pharmaceutical supply function within a French university hospital center

Doi : 10.1016/j.pharma.2021.12.007 
H. Sayin a, C. Gaillard a, b, A. Henry c, D. Cabelguenne d, X. Armoiry a, b, e,
a Faculté de pharmacie, ISPB université Claude-Bernard Lyon 1, 69008 Lyon, France 
b INSA Lyon, CNRS, MATEIS, UMR5510, UCBL, université Lyon, 69100 Villeurbanne, France 
c Service pharmaceutique, groupement hospitalier Nord, hospices civils de Lyon, 69004 Lyon, France 
d Service pharmaceutique, hospices civils de Lyon, hôpital Lyon Sud, 69495 Pierre-Bénite cedex, France 
e Service de pharmacie, hospices civils de Lyon, hôpital Édouard-Herriot, 69003 Lyon, France 

Auteur correspondant.

Résumé

Points essentiels

Le nouveau règlement européen peut avoir un impact sur les utilisateurs finaux de dispositifs médicaux (DM).
Des conséquences sont déjà visibles sur l’approvisionnement hospitalier des DM.
Des répercussions économiques sont attendues du fait du temps nécessaire sur la recherche d’alternatives.
L’examen des impacts positifs et négatifs mériterait d’être poursuivi au long cours.

Le texte complet de cet article est disponible en PDF.

Résumé

Objectif

Il est attendu que le nouveau règlement européen (MDR) sur les dispositifs médicaux (DM) ait des impacts majeurs sur le secteur industriel, mais également des conséquences sur les professionnels de santé. Notre objectif a été d’appréhender l’impact du MDR sur la fonction approvisionnement en DM des pharmacies hospitalières à l’échelle d’un centre hospitalo-universitaire français.

Matériel et méthodes

Nous avons réalisé un suivi prospectif des arrêts de commercialisation et rupture d’approvisionnement en lien direct avec le MDR entre novembre 2019 et septembre 2020. Les données ont été analysées en tenant compte de la nature des fournisseurs (statut/taille), la nature des DM (voie d’abord/classe), et des alternatives proposées. Les conséquences économiques pour les pharmacies hospitalières ont été également estimées.

Résultats

Sur la période, 96 désignations produits de DM (402 références) ont été déclarées en rupture ou arrêt, la moitié correspondant à des DM de classe IIa, et utilisées principalement pour l’abord chirurgical. Sur les 14 entreprises concernées (36 % française), la majorité était des fabricants, de taille petite/moyenne ou de taille intermédiaire. Des solutions de substitution ont été proposées pour 15 produits seulement (15,6 %). Le coût de gestion pharmaceutique de ces ruptures/arrêts a été estimé à 3052€.

Conclusion

Avant même la date officielle de son application, les impacts du MDR sur la fonction d’approvisionnement des pharmacies hospitalières se font déjà ressentir. Sur le court, moyen et long terme, un suivi prospectif des impacts, positifs ou négatifs, semblerait justifié à l’échelle des industriels, des professionnels de santé et utilisateurs finaux des DM.

Le texte complet de cet article est disponible en PDF.

Summary

Objective

The new European regulation (MDR) on medical devices (MD) is expected to have major impacts on the industrial sector, but also consequences on healthcare professionals. Our objective was to evaluate the impact of the MDR on the supply of MDs in hospital pharmacies at the level of a French university hospital.

Material and methods

We conducted a prospective follow-up of marketing cessations and supply disruptions directly related to the MDR between November 2019 and September 2020. The data were analyzed accounting for the nature of the suppliers (status/size), the nature of the MDs (route/class), and the proposed alternatives. The economic impact on hospital pharmacies was also estimated.

Results

Over this period, 96 MD product designations were declared out of stock or in cessation (total of 402 references), of which half corresponded to class IIa MDs, mainly used for surgical procedures. Of the 14 companies concerned (36% French), the majority were manufacturers, of small/medium-size or intermediate size. Substitutions were proposed for only 15 products (15.6%). The cost of pharmaceutical management of these disruptions/marketing cessations was estimated at 3052€.

Conclusion

Even before the official date of its application, the impacts of the MDR on the supply function of hospital pharmacies are already visible. In the short, medium and long term, prospective monitoring of the impacts, positive or negative, would seem to be justified at the level of manufacturers, healthcare professionals and end users of MDs.

Le texte complet de cet article est disponible en PDF.

Mots clés : Dispositifs médicaux, Marquage CE, Règlement 2017/745, Approvisionnement, Pharmacie hospitalière

Keywords : Medical devices, EC marking, 2017/745 Regulation, Supply, Hospital pharmacy


Plan


© 2021  Académie Nationale de Pharmacie. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 80 - N° 5

P. 730-737 - septembre 2022 Retour au numéro
Article précédent Article précédent
  • Simultaneous determination of ergotamine, caffeine and dipyrone in their ternary mixture by applying double divisor and first derivative ratio spectra methods
  • A. Ayman, A.M. Zeid, M.E.K. Wahba, Y. EL-Shabrawy
| Article suivant Article suivant
  • EASYSCAN : étude pilote française pour la sécurisation de l’administration des médicaments par lecture code-barres
  • E. Revel, A. Picard, L. Malet, B. Grenier, G. Susong, P. Gaillourdet, V. Breant, X. Dode

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.