S'abonner

Biomechanical analysis of locking plates for fixation of metacarpal shaft fractures: A finite element analysis - 25/11/22

Doi : 10.1016/j.otsr.2022.103340 
Jian-Feng Zhang a, , Yong Li a, Yong-Xin Huo b, Ming Yan a, Shou-Lei Liang a, Lei Wang c, Bao-Cang Wang a
a Department of orthopedics, The Second Hospital of Tangshan, Hebei, China 
b Department of Hand Surgery, The Second Hospital of Tangshan, Hebei, China 
c Department of Trauma Surgery, The Second Hospital of Tangshan, Hebei, China 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

There appears to be a paucity of knowledge about the biomechanics of locking plates for the fixation of metacarpal shaft fractures. A thorough understanding of the biomechanics of locking plates is needed to apply them correctly, optimize outcomes, and avoid complications. The purpose of this study is to investigate the biomechanics of the fixation of metacarpal fractures using locking plate-screw constructs with different numbers of screws.

Hypothesis

The difference in the number of screws in the locking plate influenced the biomechanical outcome of the metacarpal fracture.

Methods

Finite element models of third metacarpal fractures with locking plate-screw constructs were established, and the magnitude and distribution of their stresses and displacements were investigated when a vertical load of 100N was applied.

Results

For the metacarpal fracture with a locking plate and screws, the stress in the metacarpal was largely shared by the plate-screw construct. For the plate-screw construct, the stress is concentrated in the area close to the fracture line, and the 6-screw Group has the lowest failure risk since it has the lowest plate stress and the second-lowest screw stress. The implant-bone construct with 8 screws has better biomechanical stability because of minimal displacement, but increased stress on both the metacarpal bone and the screws, leading to increased failure rates.

Discussion

The stresses in the metacarpal were mostly shared by the plate-screw constructs and the screws closest to the fracture line were the most likely to break or loosen. For the implant-bone constructs, the locking plate with 2 screws was the most vulnerable to break or loosen, whereas the locking plate with 6 screws was the least likely to break or loosen. The implant-bone construct with 8 screws had better biomechanical stability, but the stresses in both the metacarpal and the screws were increased, which increased the risk of failure.

Level of evidence

IV, basic science study.

Le texte complet de cet article est disponible en PDF.

Keywords : Metacarpal bones, Finite element analysis, Bone plates, Fracture fixation, Stress concentration


Plan


© 2022  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 108 - N° 8

Article 103340- décembre 2022 Retour au numéro
Article précédent Article précédent
  • Pullout strength of connected pins in hand surgery: Effect of pin diameter and insertion angle
  • Lagsaiar Elhassan, Laela El Amiri, Sandrine Braymand, Nadia Bahlouli, Sybille Facca, Marie Cécile Sapa, Philippe Liverneaux
| Article suivant Article suivant
  • In vitro study of elution kinetics and biological activity of piperacillin/tazobactam and gentamicin in acrylic bone cement
  • Tarun Goyal, Puneet Dhamija, Gyan Vardhan, Pratima Gupta, Vivek Trikha

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.