S'abonner

Catheter versus surgical approach for the management of concomitant aortic stenosis and coronary artery disease: An inverse probability treatment weighting analysis - 25/01/23

Doi : 10.1016/j.acvd.2022.12.004 
Adèle Lérault a, Aurélien Villecourt a, Thibaud Decottignies-Dienne a, Sophie Tassan-Mangina a, Virginie Heroguelle a, Alessandro Di Cesare b, Sylvain Rubin b, Vito Giovanni Ruggieri b, Damien Metz a, Laurent Faroux a, c,
a Department of Cardiology, Reims University Hospital, 51092 Reims, France 
b Cardiac Surgery Department, Reims University Hospital, 51092 Reims, France 
c EA3801 HERVI, SFR CAP Santé, University of Reims Champagne Ardenne, 51100 Reims, France 

Corresponding author at: Department of Cardiology, Reims University Hospital, Avenue du General Koenig, 51092 Reims, France.Department of Cardiology, Reims University HospitalAvenue du General KoenigReims51092France
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Wednesday 25 January 2023
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Highlights

Patients with concomitant AS and CAD can be treated by catheter or surgery.
Patients treated by catheter have a higher co-morbidity burden.
The surgical approach is associated with a higher rate of procedural complications.
Patients treated by catheter have similar late outcomes to those treated by surgery.

Le texte complet de cet article est disponible en PDF.

Summary

Background

Two therapeutic strategies are available when aortic stenosis and coronary artery disease coexist: a transcatheter approach, with percutaneous coronary intervention followed by transcatheter aortic valve replacement; and a surgical approach, consisting of surgical aortic valve replacement combined with coronary artery bypass graft.

Aim

We sought to compare the outcomes of these two strategies.

Methods

The study population consisted of 241 patients who benefited from aortic valve replacement and coronary revascularization (transcatheter, n=150; surgery, n=91).

Results

Patients in the transcatheter population were older (83.5 vs. 71.8years; P<0.001) and had a higher Logistic EuroSCORE (11.1% vs. 5.7%; P<0.001). At 30days postprocedure, patients who had surgery exhibited more life-threatening bleedings (12.1% vs 4.5%; P=0.034), acute kidney injury (12.1% vs. 1.3%; P<0.001) and atrial fibrillation (55.6% vs. 8.7%; P<0.001). After a median follow-up of 27months, the risk of major adverse cardiovascular or cerebrovascular events did not differ significantly between the two strategies (hazard ratio [HR] 1.41, 95% confidence interval [CI] 0.97–2.04; P=0.07), whereas estimated glomerular filtration rate<60mL/min (HR 2.22, 95% CI 1.58–3.12; P<0.001), peripheral artery disease (HR 2.00, 95% CI 1.37–2.91; P<0.001) and left ventricular ejection fraction<50% (HR 1.69, 95% CI 1.12–2.55; P=0.012) were associated with a negative prognosis.

Conclusions

In our study, patients with aortic stenosis and coronary artery disease treated by catheter were older and had a higher co-morbidity burden than those treated by surgery. The surgical strategy was associated with a higher rate of 30-day complications, but long-term outcomes were similar between the two strategies.

Le texte complet de cet article est disponible en PDF.

Keywords : Aortic stenosis, Coronary artery disease, Transcatheter aortic valve replacement, Percutaneous coronary intervention, Surgical aortic valve replacement

Abbreviations : AS, CABG, CAD, CI, eGFR, HR, IPTW, LVEF, MACCE, PAD, PCI, SAVR, TAVR


Plan


 Tweet: PCI+TAVR versus SAVR+CABG: higher rate of procedural complications associated with the surgical approach, but similar late outcomes. Twitter address: @LFX51.


© 2023  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.