S'abonner

The Performance of Machine Learning Approaches for Attenuation Correction of PET in Neuroimaging: A Meta-Analysis - 03/02/23

Doi : 10.1016/j.neurad.2023.01.157 
Raymond Confidence 1, 2, Michael T. Jurkiewicz 1, 2, 3, Akin Orunmuyi 4, Linshan Liu 2, Michael Oluwaseun Dada 5, Claes N. Ladefoged 6, Jarmo Teuho 7, 8, Udunna C Anazodo 1, 2, 9,
1 Department of Medical Biophysics, Western University, London, ON, Canada. 
2 Lawson Health Research Institute, London, ON, Canada 
3 Department of Medical Imaging, Western University, London, ON, Canada. 
4 Kenyatta University Teaching, Research and Referral Hospital, Nairobi, Kenya. 
5 Department of Physics, Federal University of Technology, Minna, Nigeria. 
6 Department of Clinical Physiology, Nuclear Medicine, and PET, Rigshospitalet Copenhagen, Denmark. 
7 Turku PET Centre, Turku University, Turku, Finland. 
8 Turku University Hospital, Turku, Finland. 
9 Montreal Neurological Institute, Montreal, Quebec, Canada 

Corresponding Author: 3801 Rue University, Montreal, QC H3A 2B43801 Rue UniversityMontrealQCH3A 2B4
Sous presse. Manuscrit accepté. Disponible en ligne depuis le Friday 03 February 2023
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Purpose

This systematic review provides a consensus on the clinical feasibility of machine learning (ML) methods for brain PET attenuation correction (AC). Performance of ML-AC were compared to clinical standards.

Methods

Two hundred and eighty studies were identified through electronic searches of brain PET studies published between January 1, 2008, and August 1, 2022. Reported outcomes for image quality, tissue classification performance, regional and global bias were extracted to evaluate ML-AC performance. Methodological quality of included studies and the quality of evidence of analysed outcomes were assessed using QUADAS-2 and GRADE, respectively.

Results

A total of 19 studies (2371 participants) met the inclusion criteria. Overall, the global bias of ML methods was 0.76 ± 1.2%. For image quality, the relative mean square error (RMSE) was 0.20 ± 0.4 while for tissues classification, the Dice similarity coefficient (DSC) for bone/soft tissue/air were 0.82 ± 0.1 / 0.95 ± 0.03 / 0.85 ± 0.14.

Conclusions

In general, ML-AC performance is within acceptable limits for clinical PET imaging. The sparse information on ML-AC robustness and its limited qualitative clinical evaluation may hinder clinical implementation in neuroimaging, especially for PET/MRI or emerging brain PET systems where standard AC approaches are not readily available.

Le texte complet de cet article est disponible en PDF.

Graphical abstract




Image, graphical abstract

Le texte complet de cet article est disponible en PDF.

Keywords : Machine learning, Attenuation Correction, Synthetic-CT, Neuroimaging, PET/MRI, PET, brain PET, Systematic review


Plan


© 2023  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.