Relationship between diameter asymmetry and blood flow in the pre-communicating (A1) segment of the anterior cerebral arteries - 23/05/23

Doi : 10.1016/j.neurad.2022.10.004 
RJ van Tuijl a, , YM Ruigrok b, MEH Ophelders a, IN Vos a, IC van der Schaaf c, JJM Zwanenburg a, BK Velthuis c
a Radiology Department, Center for Image Sciences, University Medical Center Utrecht, the Netherlands 
b Department of Neurology and Neurosurgery, University Medical Center Utrecht Brain Center, the Netherlands 
c Department of Radiology University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands 

Corresponding author.

Abstract

Background

Asymmetry in diameter between pre-communicating (A1) segments of the anterior cerebral arteries is related to anterior communicating artery aneurysm formation. Diameter asymmetry definitions vary and have not been related to blood flow measurements using the same imaging modality. We aimed to evaluate the relationship between A1-diameter asymmetry and blood flow asymmetry and to define a hemodynamically significant cut-off value for A1-diameter asymmetry. We assessed sex differences between different groups of A1-asymmetry.

Materials and methods

3-Tesla time-of-flight MRA and 4D-phase-contrast MRI were performed in 122 healthy participants. Diameter and blood flow measurements were performed halfway in both A1-segments. Participants were subdivided based on A1-diameter asymmetry: ≤10% (symmetric); 11–20%; 21–30%; 31–40%; and >40% (increasing asymmetry) groups. We studied the relationship between A1-diameter asymmetry and corresponding flow asymmetry (scatterplot and correlation). A hemodynamic-based cutoff value for A1-asymmetry was determined by comparing dominant A1 blood flow in the asymmetry groups to the mean blood flow of the symmetric A1-group (linear mixed-effects model). Sex-related differences in A1-diameter, blood flow and asymmetry were assessed with t-tests.

Results

A1-diameter asymmetry was linearly related to blood flow asymmetry between dominant and non-dominant sides. A1-diameter asymmetry >30% yielded statistically significant increased blood flow in the dominant A1 compared to symmetric A1s. Men had statistically significant larger A1-diameters, higher blood flow and a similar degree of A1-diameter asymmetry compared to women.

Conclusion

A1-diameter asymmetry is linearly related to blood flow asymmetry. A >30% A1-asymmetry can be used as hemodynamically significant cut-off value. There were no sex-related differences in A1-diameter asymmetry.

Le texte complet de cet article est disponible en PDF.

Graphical abstract




Image, graphical abstract

Le texte complet de cet article est disponible en PDF.

Keywords : A1-diameter, Blood flow, Velocity pulsatility, Pre-communicating arteries, 3T MRI, 4-dimensional phase-contrast MRI

Abbreviations : A1-segment, ACA, Acom, CoW, DC, IA, ICA, MCA, TOF-MRA, UIA, vPI, 4D-PC


Plan


© 2022  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 50 - N° 4

P. 402-406 - juin 2023 Retour au numéro
Article précédent Article précédent
  • Virtual magnetic resonance elastography predicts the intraoperative consistency of meningiomas
  • Jan Saip Aunan-Diop, Mikkel Christian Schou Andersen, Ancuta Ioana Friismose, Bo Halle, Christian Bonde Pedersen, Bo Mussmann, Mads Hjortdal Grønhøj, Troels Halfeld Nielsen, Ulla Jensen, Frantz Rom Poulsen
| Article suivant Article suivant
  • Arterial transit artifacts observed on arterial spin labeling perfusion imaging of carotid artery stenosis patients: What are counterparts on symptomatology, dynamic susceptibility contrast perfusion, and digital subtraction angiography?
  • Rifat Ozpar, Yasemin Dinc, Omer Fatih Nas, Mehmet Fatih Inecikli, Mufit Parlak, Bahattin Hakyemez

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.