S'abonner

Effect of self-assembling peptide and other remineralizing agents on preventing initial enamel lesions around orthodontic brackets: An in vitro comparative study - 24/05/23

Doi : 10.1016/j.ortho.2023.100751 
Yasmin Samir Ghaly 1, , Noha A. El-Wassefy 2, Marwa Sameh Shamaa 1, Marwa Ali Tawfik 1
1 Department of Orthodontics, Mansoura University, Faculty of Dentistry, Algomhoria Street, Aldakhlia, 35516 Mansoura, Egypt 
2 Department of Dental Biomaterials, Mansoura University, Faculty of Dentistry, Mansoura, Egypt 

Yasmin Samir Ghaly, Department of Orthodontics, Mansoura University, Faculty of Dentistry, Algomhoria Street, Aldakhlia, 35516 Mansoura, Egypt.Department of Orthodontics, Mansoura University, Faculty of DentistryAlgomhoria Street, AldakhliaMansoura35516Egypt

Summary

Objective

To investigate and compare the effect of self-assembling peptide SAP (P11-4), casein phosphopeptide-amorphous calcium phosphate fluoride paste (CPP-ACPF), and fluoride varnish (FV) on preventing enamel demineralization around orthodontic brackets.

Material and methods

Orthodontic brackets were bonded to the buccal surfaces of 80 freshly extracted human maxillary premolars. Teeth were randomly assigned to four groups (n=20) according to the remineralizing agent used as follows: SAP (P11-4) group (Curodont™ Protect/Credentis), CPP-ACPF group (MI Paste Plus®/Recaldent™), fluoride varnish group (Profluoride varnish®/VOCO), and control group. All products were applied according to the manufacturer's instructions. Specimens were cycled in daily refreshed demineralizing and remineralizing solutions for 8h and 16h, respectively, for 28 days. The calcium/phosphorus ratio (Ca/P) and surface microhardness (SMH) were evaluated at baseline and at two and four weeks. Two-way ANOVA (analysis of variance), one-way ANOVA and repeated measures ANOVA were used for statistical analysis.

Results

Two-way ANOVA demonstrated significant differences between remineralizing agents and time points. After 4 weeks, the SAP (P11-4) group had had significantly higher Ca/P ratio and SMH (1.68±0.11 and 346.47±55.38) compared to other groups, followed by CPP-ACPF (1.52±0.19 and 283.53±64.75), FV (1.37±0.14 and 262.80±82.98), and the control group (1.31±0.10 and 213.00±41.95). Significantly higher Ca/P ratio and SMH were observed at 2 weeks in the control group (1.44±0.10 and 269.63±57.37) and FV group (1.52±0.09 and 321.17±55.24) compared to 4 weeks. No significant differences were found regarding Ca/P ratio and SMH at 2 weeks in the CPP-ACPF (1.55±0.15 and 295.14±53.88) and SAP P11-4 groups (1.64±0.10 and 320.18±58.04) compared to 4 weeks.

Conclusion

SAP (P11-4) had the greatest remineralizing efficacy compared to FV and CPP-ACPF. Moreover, extended period of time improved the preventive efficacy of SAP (P11-4) compared to the other regimens.

Le texte complet de cet article est disponible en PDF.

Keywords : Self-assembling peptide, Casein phosphopeptide-amorphous calcium phosphate, Fluoride varnish, Energy dispersive X-ray spectroscope, Surface micro hardness, Orthodontics


Plan


© 2023  CEO. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 21 - N° 2

Article 100751- juin 2023 Retour au numéro
Article précédent Article précédent
  • Shear bond strength of adhesive precoated brackets: A comparative in vitro study
  • Mary Miller, Htwe H. Mon, Xiaoming Xu, Andrew Chapple, Peter Dupree, Richard W. Ballard, Paul Armbruster
| Article suivant Article suivant
  • Introducing and assessing the efficacy of a novel method to reduce enamel damage after orthodontic bracket removal using two herbal-based resin colouring agents: An in vitro study
  • Farzaneh Ahrari, Navid Ramezanian, Zahra Ahmadi, Hamideh Sadat Mohammadipour

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.