S'abonner

Comparative study of a Y- anatomical and innovative locking plate versus double plate for supracondylar humeral fracture - 07/06/23

Doi : 10.1016/j.otsr.2022.103380 
Hugo Barret a, , Romain Ceccarelli b, Paul Vial D’Allais a, Matthias Winter c, Michel Chammas a, Bertrand Coulet a, Cyril Lazerges a
a CHRU de Montpellier, Montpellier, France 
b CHU de Nice, Nice, France 
c Saint-Jean Clinic, Antibes-Cagnes-sur-Mer, France 

Corresponding author.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Wednesday 07 June 2023
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Introduction

There is no “gold standard” for the type of plate to be used for distal extra-articular humeral fractures; the most used is plating of each column. The objective was to evaluate the short-term clinical and radiological results of a Y- anatomical and innovative locking plate (YALP).

Hypothesis

The hypothesis is: this anatomical and innovative locking plate will produce satisfactory and reliable results on extra-articular distal humerus fracture superior to double plate fixation.

Materials and methods

In a retrospective observational multicenter study, all patients with a distal humerus fracture type 13 A2.2 according to AO classification fixed with a new Y-plate (YALP) were compared to the results of double plate fixation for the same type of fracture. With a follow-up of more than 12 months, the objective and subjective clinical elbow criteria as well as the overall function of the upper limb and radiological assessment were collected.

Results

With an average follow up of 24±11 months, 26 patients met the inclusion criteria and received a YALP and 24 patients received double plate. All patients whose fracture had healed except one were pain-free (mean VAS 0.3±0.6). All patients had good subjective results (mean SEV 96%±4). Elbow function was excellent (mean total MEPS 96±4) with normal triceps strength (23/24 patients had a triceps strength graded 5/5 and one patient 4/5) and range of motion (flexion 139±8, extension −7±8 and pronosupination greater than 155 degrees). The operating time was shorter in the YALP group (84 ± 23minutes versus 97 ± 28minutes, p=0.03). The double plate group had more complications; the overall complication rate was significantly higher (p=0.02) in the double 90-degree plate group (12/24, 50%) with four nonunions, four symptomatic ulnar nerves, three hardware removals for pain and one radial nerve injury versus 5/26 complications (19%, p=0.02) in the Y-plate group: one iliac graft for nonunion, 1 plate removal due to functional discomfort, 1 twisted YALP, 1 broke interfragmentary screw and one symptomatic ulnar nerve. DASH, SEV, MEPS scores and flexion-extension range were better in the YALP group.

Discussion

YALP produces satisfactory results in supracondylar fractures of the distal humerus. The results of YALP appear to be better than the results with two 90° plates for the same fracture type with a shorter operative time and easier management of fractures with proximal diaphyseal extension.

Level of evidence

III; case control study.

Le texte complet de cet article est disponible en PDF.

Keywords : Distal extra-articular humerus fracture, Y-anatomical and innovative locking plate (YALP), Trans-tricipital approach


Plan


© 2022  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.