S'abonner

“Comparison of the efficacy of Erich arch bars, IMF screws and SMART Lock Hybrid arch bars in the management of mandibular fractures- A Randomized clinical study” - 10/01/25

Doi : 10.1016/j.jormas.2025.102217 
Revanth Kumar Salavadi a, , Jangam Sowmya b, Baswa Mani kumari c, Kavitha P Kamath d, Pradeep S Anand a, Nambi Muni Roopesh Kumar e, Pranavi Jadhav f
a Department of Dentistry, ESIC Medical College and Hospital, Hyderabad, Telangana, India 
b Department of Orthodontics, Army College of Dental Sciences, Telangana, India 
c Department of Plastic Surgery, ESIC Medical College and Hospital, Hyderabad, Telangana, India 
d Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences University, Chennai, Tamilnadu, India 
e Department of Plastic Surgery, Nizams Institute of Medical Sciences, Hyderabad, Telanagana, India 
f Department of Dentistry, Arundhati Institute of Medical Sciences, Telangana, India 

Corresponding author.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Friday 10 January 2025

Abstract

Purpose

The purpose of this study was to assess and compare the efficacy of Erich Arch Bar (EAB), Inter Maxillary Fixation (IMF) screws and SMART Lock Hybrid arch bar (HABs) in the treatment of mandibular fractures.

Materials and Methods

A prospective randomized clinical study was carried out in the Department of Dentistry at ESIC Hospital in Hyderabad from August 2021 to August 2023. The study comprised of three groups (EAB group (31), IMF screw group (33) and HABs group (29)).Primary outcome variable was occlusal stability. Secondary outcome variables were time taken to apply the device, glove perforation, oral hygiene assessment by Modified Turskey Gilmore Plaque index, Quality of life (QOL) assessment by General Oral Health Assessment Index (GOHAI), mucosal growth and dental injuries.

Results

The average application time for EAB, IMF screws and HABs was 78 min, 15 min and 19 min respectively. No significant difference was noticed in occlusal stability at the end of 1 week and 4 weeks follow-up period. There was no statistically significant difference in instances of dental injury among the three groups. However, there were statistically significant differences (P < 0.05) in the time taken to apply, glove perforation, oral hygiene levels, mucosal overgrowth and total GOHAI score among the 3 groups.

Conclusion

HABs and IMF screws may be recommended over EABfor MMF inmandibular dentate segment fracture management due to their advantages including quick application, enhanced occlusal stability, and QOL, all of which are required for a better functional outcome

Le texte complet de cet article est disponible en PDF.

Keywords : Maxillomandibular fixation, Erich arch bar, IMF screws, Smart lock hybrid arch bar, Modified arch bar, Quality of life


Plan


© 2025  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.