S'abonner

Enhancing Precision and Personalization in Surgical Management of Osteogenesis Imperfecta Through Advanced Technologies: A Case Study - 03/06/25

Doi : 10.1016/j.irbm.2025.100900 
Yary Volpe a, , Simone Lazzeri b
a Department of Industrial Engineering of Florence, University of Florence, via di Santa Marta 3, Firenze, Italy 
b Ospedale S. Chiara, Largo Medaglie d'Oro 9, Trento, Italy 

Corresponding author.

Abstract

Background and Objective

The paper aims to demonstrate the integration of advanced technologies, including computed tomography (CT), computer-aided design (CAD), and additive manufacturing, for precise surgical planning and personalized solutions in the management of Osteogenesis Imperfecta (OI). The main research question is to determine how these technologies can be utilized to achieve successful surgical outcomes in severe cases of OI, such as the one presented in this study.

Methods

The study involved an 11-year-old child with OI who suffered from a closed right diaphyseal femur fracture and severe lower extremity abnormalities. Virtual and physical planning procedures were carried out using CAD software based on patient-specific CT models. The length of the proximal and distal segments, cutting planes, and osteotomies were precisely defined to achieve the desired surgical corrections. Additionally, 3D models of the bones and bony segments were manufactured using additive manufacturing to physically recreate the surgical procedure.

Results

The surgical treatment involved the correction of the right femur fracture and the left tibia and fibula in the first procedure, followed by the correction of the remaining segments in a second procedure. The Fassier-Duval telescopic intramedullary nail was used to stabilize the fracture and the osteotomy sites. The entire treatment course, from the first surgery to achieving partial weight-bearing, spanned approximately 15 weeks, including the two surgical procedures and staged rehabilitation. Post-surgery, the patient showed significant functional improvement, including the ability to stand and walk with assistance.

Conclusion

The integration of advanced technologies in surgical planning for OI patients has shown promising results, leading to improved patient outcomes and reduced complications. This approach has the potential to enhance the accuracy of preoperative planning and provide personalized and precise solutions, ultimately elevating the overall quality of healthcare for OI patients.

Le texte complet de cet article est disponible en PDF.

Graphical abstract




Le texte complet de cet article est disponible en PDF.

Highlights

Advanced tech improves surgical planning for Osteogenesis Imperfecta (OI).
CAD and CT enable precise virtual and physical surgery simulations.
3D-printed models assist in complex bone reconstruction procedures.
Two-stage surgery leads to significant functional improvement in OI patient.
Personalized solutions reduce complications and enhance surgical outcomes.

Le texte complet de cet article est disponible en PDF.

Keywords : Computer aided design, Additive manufacturing, Surgery planning, Osteogenesis Imperfecta


Plan


© 2025  AGBM. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 46 - N° 4

Article 100900- août 2025 Retour au numéro
Article précédent Article précédent
  • Characterization and In Vivo Evaluation of Phosphate-Based Glass/TiO2 for Skull Prosthetic Application
  • Ana Lucía Sánchez-Alfonso, Lorena Gaytán-Tocavén, Luz Eugenia Alcantara-Quintana, Raul Gerardo Paredes, Criseida Ruiz-Aguilar
| Article suivant Article suivant
  • Effects of the Printing Angle on the Properties of Titanium Devices Printed by Additive Manufacturing: a Systematic Review
  • Juliana Dias Corpa Tardelli, Júlia Sacilotto, Lucas Barcelos Otani, Andréa Cândido dos Reis

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.