S'abonner

Longitudinal changes of electrical impedance tomography-based best PEEP in obese patients undergoing laparoscopic surgery: A prospective physiological study - 04/07/25

Doi : 10.1016/j.accpm.2025.101569 
Gaetano Scaramuzzo a, b, , Paolo Priani a, Pierluigi Ferrara a, Marco Verri b, Federica Montanaro b, Riccardo La Rosa a, Gianmaria Cammarota c, Carlo Alberto Volta a, b, Savino Spadaro a, b
a Department of Translational Medicine, University of Ferrara, Ferrara, Italy 
b Department of Emergency, Azienda Ospedaliera Universitaria Sant’Anna, Ferrara, Italy 
c Department of Translational Medicine, Università Degli Studi del Piemonte Orientale “Amedeo Avogadro”, Novara, Italy 

Corresponding author.

Abstract

Background

During laparoscopic surgery, there is an increased tendency for lung collapse. Individualized PEEP has shown possible advantages in obese patients undergoing laparoscopic procedures, but the optimal timing for titration and the evolution of lung regional mechanics have not been extensively explored.

Methods

Patients with Class I/II Obesity undergoing laparoscopic surgery for abdominal procedures were monitored using 16 electrodes Electrical Impedance Tomography (EIT) and underwent a decremental PEEP titration trial at 3 timepoints: after anesthesia induction (T1), after positioning and pneumoperitoneum (T2) and after laparoscopy (T3). EIT-derived lung regional collapse (EITCO) and overdistension (EITOD) were recorded, as well as respiratory mechanics, hemodynamic and surgical data. The best PEEP according to EIT (PEEPEIT) was calculated at each timepoint as the intersection between regional collapse and overdistention.

Results

We enrolled 31 patients with a median age of 63 [49−74] years and a BMI of 36 [32−37] kg m−1. During surgery, PEEPEIT at T1 and T2 were respectively 10[9–11.5] and 13.9[12.6–15] cmH2O (p < 0.001), with a median increase of 3 [2–4] cmH2O, a range of increase of 0–7 cmH2O and a coefficient of increase variation of 60.8%. The difference in PEEPEIT between T2 and T1 did not correlate with intrabdominal pressure (r = −0.03, p = 0.88), while a significant association was found with trunk inclination (p = 0.018, r = 0.42).

Conclusions

EIT-based best PEEP changes dynamically and non-homogeneously during laparoscopic surgery in class I/II obese patients. PEEP reassessment is required to guarantee the application of protective mechanical ventilation throughout the entire course of anesthesia.

Registration

clinicaltrials.gov under number NCT05554536.

Le texte complet de cet article est disponible en PDF.

Keywords : Obesity, PEEP setting, Laparoscopy, Electrical impedance tomography, Positioning


Plan


؆ Clinical trial number registration Clinicaltrial.gov registration number: NCT05554536 (link: NCT05554536).


© 2025  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 44 - N° 5

Article 101569- septembre 2025 Retour au numéro
Article précédent Article précédent
  • Mortality of cancer patients with septic shock: A nation-based cohort analysis of 77,888 patients
  • Antoine Bianchi, Yann Brousse, Ines Lakbar, Vanessa Pauly, Veronica Orleans, Guillaume Fond, Gary Duclos, Laurent Zieleskiewicz, Djamel Mokart, Laurent Boyer, Marc Leone
| Article suivant Article suivant
  • Effects of intravenous paracetamol on mean arterial pressure in critically ill patients: A systematic review and meta-analysis with trial sequential analysis
  • Simone Messina, Simona Ferro, Cristina Santonocito, Carmelo Minardi, Mateusz Zawadka, Filippo Drago, Alberto Noto, Filippo Sanfilippo

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.