S'abonner

Effect of cricoid pressure on tracheal intubation time during C-MAC video laryngoscopy: A Randomized Controlled Trial - 02/10/26

Doi : 10.1016/j.accpm.2026.101840 
Smitha CB, Kunal Singh ⁎ , Amarjeet Kumar, Nishant Sahay, Ajeet Kumar, Neeraj Kumar
 Department of Anaesthesiology, All India Institute of Medical Sciences, Patna, India 

⁎ Corresponding author.

Abstract

Background

Cricoid pressure is routinely used during rapid sequence induction; however, its impact on tracheal intubation when using either direct or video laryngoscopy has not been clearly established. Studies suggest that the use of cricoid pressure may prolong intubation time and increase the difficulty of intubation. We conducted a randomized controlled trial to assess the effect of cricoid pressure on tracheal intubation during C-MAC video laryngoscopy in adult patients scheduled for elective surgery.

Methods

A total of 100 adult patients scheduled for elective surgery under general anesthesia participated in this double-blind, randomized controlled trial. They were randomly assigned to two groups: the cricoid pressure group and the sham group, each consisting of 50 patients. The primary outcome of the study was intubation time, with secondary outcomes including the number of intubation attempts, percentage of glottic opening scores, Visual Analogue Scale for the difficulty of laryngoscopy or endotracheal tube advancement into the trachea, and postoperative hoarseness.

Results

Demographic data and airway parameters were comparable across the two groups, with no significant differences. In the cricoid pressure group, the mean intubation time was marginally longer (35.6 ± 8.03 s) than the sham group (31.2 ± 9.36 s), with a mean difference of 4.42 seconds, which was statistically significant ( P  = 0.013). The number of intubation attempts, percentage of glottic opening scores, visual analogue scale, and postoperative hoarseness were similar between groups, with no statistically significant differences.

Conclusion

The application of cricoid pressure was associated with a prolongation of intubation time; however, the number of intubation attempts did not differ significantly.

Registration

Clinical Trials Registry–India (CTRI/2023/02/049436)

Le texte complet de cet article est disponible en PDF.

Keywords : Airway management, Cricoid cartilage, Laryngoscope, Rapid sequence induction and intubation


Plan


© 2026  Société Française d'Anesthésie et de Réanimation (SFAR). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 45 - N° 6

Article 101840- novembre 2026 Retour au numéro
Article précédent Article précédent
  • Percutaneous dilatational tracheostomy and thyroid isthmus penetration (PETRIS)
  • Aleš Rára, Michal Soták, Martin Hynek, Karol Kovačič, Tomáš Filipovský, Tomáš Tyll
| Article suivant Article suivant
  • Association between invasive intracranial pressure monitoring and 1-year functional outcome in ICU patients with severe stroke: a pre-planned ancillary study of the SPICE prospective cohort (SPICE-ICP)
  • David Rolland, Romain Sonneville, Mikael Mazighi, Marie Hélène Pari, Léa Meyer, Younès Brahimi, Mélanie Doirado, Magalie Collet, Etienne Gayat, Jacques Duranteau, Charles Grégoire, Tarek Sharshar, Giulia Naim, David Cortier, Paul-Henri Jost, Arnaud Foucrier, François Bagate, Etienne De Montmollin, Grégory Papin, Bertrand Guidet, Sarah Benghanem, Loïc Le Guennec, Bruno Megarbane, Karim Toumert, Alexandre Demoule, Jean-Luc Diehl, Sébastien Tanaka, David Osman, Pierre Pasquier, Fariza Lamara, Alain Cariou, Stephane Legriel, Isabelle Crassard, Perrine Boursin, Jean-François Timsit, France Woimant, Vincent Degos, Alice Jacquens

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.