S'abonner

L001 Abdominal aortic aneurysm: searching for plasma biomarkers - 17/04/09

Doi : 10.1016/S1875-2136(09)72416-7 
A. Acosta Martin 1, A. Panchaud 2, M. Chwastyniak 1, B. Gallis 2, P. Amouyel 1, D. Goodlett 2, F. Pinet 1
1 Unité Inserm 744, Institut Pasteur de Lille, Lille, France 
2 Medicinal Chemistry, University of Washington, Seattle, USA 

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Aortic Abdominal Aneurysm (AAA) is characterized by an increase of diameter (>1.5 times to reference diameter) and loss of parallelism of the vessel wall. This disease is more often asymptomatic and its rupture is responsible for 1-4 % of mortality in males older than 65 years. Surgery treatment is possible in the case of detection by echography but no specific biological markers are available. In order to identify markers of AAA, we have established a clinical protocol, named CORONA, in which 265 patients undergoing coronary bypass grafting were recruited from 2002 to 2006 in CHRU of Lille. For 6.4 % of them (n=17), an AAA was detected by abdominal ultrasound after the bypass. From the 265 patients included, 98 % of plasma samples, 89 % of macrophages cultures and 40 % of smooth muscle cells cultures were obtained to compare proteomes between aneurismal and non-aneurismal patients. First, every AAA patient was matched to three non-AAA, according to their age, tobacco consumption, arterial hypertension, diabetes and dyslipidemia. Then, according to this classification, the biological and clinical data of the CORONA sample set, composed of 68 plasma samples from 17 AAA and 51 non-AAA bypass patients, were analyzed by exact nonparametric inference tests using StatXact.8 software. Next, proteomic analysis of plasma samples by a powerful data independent mass spectrometry method was performed in order to obtain qualitative as well as quantitative information. The results obtained in the statistical analysis showed that there are not important significant differences in the biological and clinical characteristics between both groups of patients, suggesting that the potential biomarkers found in the proteomic analysis will be more specific for AAA than in the case that control samples were from completely healthy patients. Regarding plasma proteome analysis, around 1000 plasma proteins were identified with false positive discovery rate < 1 %. From identified proteins, one third are multiple hits (at least 2 peptides per protein were identified), and from those around 75 proteins might be involved in AAA pathology (matrix proteins, proteases and inflammation proteins). The quantification of these proteins is still under work.

Le texte complet de cet article est disponible en PDF.

© 2009  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 102 - N° S1

P. S117 - mars 2009 Retour au numéro
Article précédent Article précédent
  • K012 Pharmacological blockade or genetic deletion of AT2R abolishes flow-induced structural remodeling in rat and mice resistance arteries in vivo
  • J. Lafarge, N. Clere, A.-L. Guihot, S. Faure, D. Henrion
| Article suivant Article suivant
  • L002 Étude des modifications post-traductionnelles des protéines contractiles lors du remodelage ventriculaire gauche post-infarctus
  • E. Dubois, C. Cieniewski-Bernard, P. Mulder, H. Drobecq, C. Flahaut, C. Thuillez, P. Amouyel, V. Richard, F. Pinet

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.