S'abonner

Observatoire national de la radiothérapie : rapport de l’enquête conduite en 2008 sur l’année 2007 - 06/10/09

Doi : 10.1016/j.canrad.2009.07.010 
B. Chauvet a, , M. Bolla a, A. Alies-Patin b, C. Bara c, M. Bourguignon d, G. Chantôme c, F. Eschwège a, S. Estivalet e, P. Fau e, E. Fournie c, F. Lipinski a, f, J.-J. Mazeron a, F. Mornex a, Y. Pointreau g, H. Weissmann b
a Société française de radiothérapie oncologique (SFRO), 45, rue des Saints-Pères, 75006 Paris, France 
b Caisse nationale d’assurance maladie, 26–50, avenue du Professeur-André-Lemierre, 75986 Paris cedex 20, France 
c Institut national du cancer (Inca), 52, avenue André-Morizet, 92513 Boulogne-Billancourt cedex, France 
d Autorité de sûreté nucléaire (ASN), 6, place du Colonel-Bourgoin, 75012 Paris, France 
e Société française de physique médicale, institut Curie, 26, rue d’Ulm, 75248 Paris cedex 05, France 
f Syndicat national des oncologues radiothérapeutes, 62, boulevard de Latour-Maubourg, 75007 Paris, France 
g Société française des jeunes radiothérapeutes oncologues (SFJRO), centre Antoine-Béclère, faculté de médecine, 45, rue des Saint-Pères, 75006 Paris, France 

Auteur correspondant. Institut Sainte-Catherine, BP 846, 84082 Avignon cedex 2, France.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 5
Iconographies 4
Vidéos 0
Autres 0

Résumé

Nous présentons ici les résultats les plus significatifs de l’enquête réalisée pour la deuxième année consécutive au titre de l’Observatoire national de radiothérapie. Les établissements, services et cabinets de radiothérapie ont été invités à transmettre des données concernant leurs plateaux techniques, leur activité et l’effectif des professionnels y travaillant au 31 décembre 2007. Parmi 179 centres recensés en France, 159 ont participé (90 %) dont 144 qui ont répondu aux deux enquêtes 2006 et 2007. Le parc français était composé de 411 appareils de traitement dont 384 accélérateurs linéaires et 12 télécobalts. Un an auparavant, l’observatoire recensait 371 accélérateurs et 26 télécobalts. La proportion d’accélérateurs de 15 ans et plus demeure stable à 11 %. Les centres de radiothérapie étaient ouverts aux traitements 50heures par semaine en moyenne, à quoi il convient d’ajouter 9,5 % de temps d’occupation machine consacré à la maintenance et au contrôle qualité. Le manque de scanographes dédiés restait un handicap : 158 des 159 centres avaient accès à un scanographe, mais seulement 78 (50 %) avaient un scanographe dédié, situation stable par rapport à 2006. La proportion de centres équipés d’un logiciel de double calcul des unités moniteur (UM) est passée de 51 à 58 %. En 2007, deux tiers des centres n’appliquaient la dosimétrie in vivo à aucun traitement et seuls 18 % l’appliquaient à plus de 50 % des traitements, ce qui reflète à la fois le manque d’équipements et la difficulté d’application des contrôles à certains traitements. L’activité était stable autour de 190 000 traitements par an. La radiothérapie tridimensionnelle avec histogramme dose–volume était utilisée pour plus de la moitié des traitements dans 77,2 % des centres privés et 50 % des centres publics. La radiothérapie conformationnelle avec modulation d’intensité restait peu répandue. La démographie était stable pour les oncologues radiothérapeutes et les manipulateurs et s’améliorait pour les physiciens : +7,6 % entre 2006 et 2007. L’analyse par région montre une distribution relativement homogène sur l’ensemble du territoire en matière d’équipements, d’activité et de personnels. La Société française d’oncologie radiothérapique (SFRO) et ses partenaires souhaitent poursuivre cet observatoire. Les centres de radiothérapie seront donc invités au cours du dernier trimestre 2009 à apporter de nouveau leur concours à cette enquête dont l’intérêt est reconnu tant par les professionnels et leurs instances représentatives que par les autorités administratives.

Le texte complet de cet article est disponible en PDF.

Abstract

For the second year, the French Radiotherapy Database presents information from French radiation oncology centers. Among 179 centers, 159 have participated (90 %). The number of accelerators increased from 371 to 384 between 2006 and 2007, 11 % of these machines are more than 15 years old. On average, centers are open 50hours per week for treatment and 9.5 % more for maintenance. The lack of dedicated CT remains a difficulty: 158 from 159 centers have an access to a CT, but only 50 % have a dedicated scanner. There is no progress compared to 2006. The proportion of centers having a MU double calculation system has increased from 51 to 58 %. Two thirds of centers do not implement in vivo dosimetry. The activity is stable around 190 000 treatments per year. Three-dimension conformal radiotherapy is used for more than half of treatments in 77.2 % of private centers and 50 % of public hospitals. Intensity modulated radiotherapy remains rarely used. The number of radiation oncologists and technologists remains stable. The number of radiophysicists has increased from 7.6 %. Despite some progress, the difficulties of this speciality persist in France and are equally distributed across all regions, and between private and public centers. In 2009, the French Society for Radiation Oncology and the associated partners will continue this survey, which interest is recognized by both professionals and health administrations.

Le texte complet de cet article est disponible en PDF.

Mots clés : France, Radiothérapie, Enquête, Équipements, Activité, Démographie

Keywords : France, Radiation therapy, Survey, Facilities, Activity, Demography


Plan


© 2009  Société française de radiothérapie oncologique (SFRO). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 13 - N° 6-7

P. 466-470 - octobre 2009 Retour au numéro
Article précédent Article précédent
  • Sécurité en radiothérapie : résultats de trois ans d’expérience avec la Mission nationale d’expertise et d’audits hospitalier (MEAH)
  • D. Talandier, A.-T. Tajahmady, S. Woynar
| Article suivant Article suivant
  • Place de la radiothérapie dans le traitement des lymphomes non hodgkiniens
  • L. Quero, C. Hennequin, P. Brice

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.