Étude de la dosimétrie in vivo par semi-conducteurs EPD-20 dans les conditions de l’irradiation corporelle totale - 05/02/10

Doi : 10.1016/j.canrad.2009.09.001 
M. Besbes a, , H. Mahjoubi b, L. Kochbati a, A. Ben Abdennabi a, L. Farhat c, S. Abdessaied a, L. Salem a, H. Frikha a, C. Nasr Ben Ammar a, D. Hentati a, W. Gargouri a, T. Messai a, F. Benna a, M. Maalej a
a Service de radiothérapie oncologique, institut Salah-Azaiz, boulevard 9 Avril Bab Saadoun, 1006 Tunis, Tunisie 
b Département de biophysique, institut supérieur des technologies médicales de Tunis, rue Zouhair-Essafi, 1006 Tunis, Tunisie 
c Service de radiothérapie oncologique, CHU Habib-Bourguiba, 3029 Sfax, Tunisie 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 5
Iconographies 4
Vidéos 0
Autres 0

Résumé

Objectif de l’étude

L’objectif de ce travail était l’étude de la dosimétrie in vivo pratiquée dans une série de 54 patients conditionnés par irradiation corporelle totale à l’institut Salah-Azaiz de Tunis depuis l’année 2004 et la comparaison des doses mesurées à celles calculées analytiquement a posteriori.

Patients et méthodes

L’irradiation a été effectuée à l’accélérateur linéaire (Clinac® 1800, Varian, Palo Alto, États-Unis) en utilisant soit des photons de 18 MV soit de 6 MV en fonction de l’épaisseur du patient au niveau de l’abdomen. La dose reçue a été mesurée par des semi-conducteurs de type-p EPD-20 qui étaient préalablement calibrés à l’aide d’une chambre d’ionisation « PTW type Farmer » de 0,6cm3 dans un fantôme solide constitué de plaques de 40,40cm2 en plexiglas. La dose totale prescrite dans cette série de 54 patients au niveau de l’abdomen était de 10Gy à raison de 3,33Gy par séance en trois fractions séparées de 24heures et de 9Gy au niveau des poumons en les protégeant par un cache personnalisé en cerrobend pendant la seconde séance de l’irradiation.

Résultats

Une étude des facteurs influant la réponse des semi-conducteurs dans le cas de l’irradiation corporelle totale comme l’inclinaison du faisceau d’irradiation (0–90°) et la température du milieu (22–40°C) a montré, respectivement, des variations maximales de 5 à 7 %. Dans nos conditions d’irradiation, ces facteurs correctifs étaient de moins de 1 %. L’analyse des résultats de la dosimétrie in vivo a montré que les rapports des doses moyennes mesurées à celles calculées analytiquement a posteriori au niveau de l’abdomen, du médiastin, du poumon droit et de la tête étaient respectivement de 1,005, 1,007, 1,013 et 1,008 avec une déviation standard « type A » respectives de 3,04 %, 2,37 %, 7,09 % et 4,15 %.

Conclusion

La dosimétrie in vivo par semi-conducteurs était en accord avec la dosimétrie par calcul. Cependant, la dosimétrie in vivo par semi-conducteurs est le moyen qui peut rendre compte de la dose réellement reçue instantanément par le patient lors de l’irradiation corporelle totale compte tenu des nombreux facteurs que ne peut prendre en compte le calcul : le mouvement du malade, le mouvement de l’organe lui-même et l’hétérogénéité du milieu.

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose

The objective of this work was the study of in vivo dosimetry performed in a series of 54 patients receiving total body irradiation (TBI) at the Salah-Azaiz Institute of Tunis since 2004. In vivo dosimetry measurements were compared to analytically calculated doses from monitor units delivered.

Patients and method

The irradiation was conducted by a linear accelerator (Clinac® 1800, Varian, Palo Alto, USA) using nominal X-rays energies of 6 MV and 18 MV, depending on the thickness of the patient at the abdomen. The dose was measured by semi-conductors p-type EPD-20. These diodes were calibrated in advance with an ionization chamber “PTW Farmer” type of 0.6cm3 and were placed on the surface of plexiglas phantom in the same TBI conditions. A study of dosimetric characteristics of semi-conductors EPD-20 was carried out as a function of beam direction and temperature. Afterwards, we conducted a comparative analysis of doses measured using these detectors during irradiation to those calculated retrospectively from monitor units delivered to each patient conditioned by TBI.

Results

Experience showed that semi-conductors are sensitive to the angle of beam radiation (0–90°) and the temperature (22–40°C). The maximum variation is respectively 5 and 7%, but in our irradiation conditions these correction factors are less than 1%. The analysis of the results of the in vivo dosimetry had shown that the ratio of the average measured doses and analytically calculated doses at the abdomen, mediastina, right lung and head are 1.005, 1.007, 1.0135 and 1.008 with a standard deviation “type A” respectively of 3.04, 2.37, 7.09 et 4.15%.

Conclusion

In vivo dosimetry by semi-conductors is in perfect agreement with dosimetry by calculation. However, in vivo dosimetry using semiconductors is the only technique that can reflect the dose actually received instantly by the patient during TBI given the many factors that calculation can not take into account: patient and organs motions and the heterogeneity of the targets.

Le texte complet de cet article est disponible en PDF.

Mots clés : Dosimétrie in vivo, Détecteurs semi-conducteurs, Irradiation corporelle totale, Dose patient

Keywords : In vivo dosimetry, Semi-conductors, Total body irradiation, Patient dose


Plan


© 2009  Société française de radiothérapie oncologique (SFRO). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 14 - N° 1

P. 29-33 - janvier 2010 Retour au numéro
Article précédent Article précédent
  • Cartographie et gestion des risques en radiothérapie : un travail commun du département de radiothérapie et du département de la qualité et de la gestion des risques de l’institut Jean-Godinot
  • T.D. Nguyen, I. Devie, M. Heusghem, N. Gaillot-Petit, M. Loiseau
| Article suivant Article suivant
  • Rationale for carbon ion therapy in high-grade glioma based on a review and a meta-analysis of neutron beam trials
  • D. Maucort-Boulch, M.-H. Baron, P. Pommier, D.C. Weber, J.-E. Mizoe, J. Rochat, J.-P. Boissel, J. Balosso, H. Tsujii, E. Amsallem

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.