S'abonner

Radiothérapie conformationnelle avec modulation d’intensité (RCMI) guidée par l’image : impact de l’augmentation du volume irradié à faible dose ? - 24/09/10

Doi : 10.1016/j.canrad.2010.07.227 
A. Lisbona a, 1, D. Averbeck b, c, d, 1, S. Supiot a, G. Delpon a, D. Ali e, F. Vinas e, C. Diana e, C. Murariu e, f, J.-L. Lagrange e, f, 1,
a CLCC Nantes-Atlantique, boulevard Jacques-Monod, 44805 Saint-Herblain, France 
b IRSN/CEA, 92260 Fontenay-aux-Roses, France 
c Institut Curie, 91405 Orsay, France 
d UMR3348 CNRS, 91405 Orsay, France 
e Hôpital Henri-Mondor, AP–HP, 54, avenue du Maréchal-de-Lattre-de-Tassigny, 94000 Créteil, France 
f Université Paris-Est Créteil Val-de-Marne, 61, avenue du Général-de-Gaulle, 94010 Créteil, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 8
Iconographies 1
Vidéos 0
Autres 0

Résumé

La radiothérapie guidée par l’image (IGRT) et la radiothérapie conformationnelle avec modulation d’intensité (RCMI) sont utilisées de plus en plus fréquemment. Certains auteurs recommandent même que les irradiations par RCMI soient toujours guidées par l’image. Le contrôle de l’alignement, du réalignement du patient et de la position des cibles en radiothérapie externe sont effectués de plus en plus par une imagerie de qualité radiologique. Toutefois ces nouvelles procédures provoquent des irradiations à faibles doses dans des volumes qui peuvent être importants. Les doses physiques dues à cette imagerie sont connues, quantifiables et traçables. Lors de l’évaluation et la comparaison de ces nouvelles techniques, comparativement aux techniques classiques (radiothérapie tridimensionnelle ou classique), la prise en compte des volumes recevant de faibles doses ainsi que des doses relativement élevées (10–50Gy) doit être considérée. En effet, les effets secondaires des faibles doses ainsi que le risque de cancers secondaires avec ces nouvelles techniques sont mal connus. À faible niveau de dose (<100mGy), plusieurs phénomènes et paramètres sont à considérer pour estimer le risque pour la santé : induction de gènes et activation de protéines impliquées dans la réparation cellulaire, activation de signalisation des dommages, induction d’effet bystander, radio-adaptation, hypersensibilité à faible dose et sensibilité individuelle. L’analyse faite sur l’apparition de cancers secondaires hors du volume cible montre que, à l’exception du dernier paramètre, la contribution des autres facteurs est actuellement considérée comme étant plutôt protectrice du point de vue du risque de cancérogenèse. Le manque de recul concernant ces nouvelles techniques et cette question devrait nous conduire à une certaine prudence, à la mise en place d’une surveillance particulière des populations de jeunes adultes ou d’enfants devant recevoir une RCMI. Il est recommandé dans les comptes rendus de fin de traitement d’au moins rapporter la dose liée au guidage par l’image.

Le texte complet de cet article est disponible en PDF.

Abstract

Image-guided radiotherapy (IGRT) combined or not with intensity-modulated radiation therapy (IMRT) are new and very useful techniques. However, these new techniques are responsible of irradiation at low dose in large volumes. The control of alignment, realignment of the patient and target positioning in external beam radiotherapy are increasingly performed by radiological imaging devices. The management of this medical imaging depends on the practice of each radiotherapy centre. The physical doses due to the IGRT are however quantifiable and traceable. In one hand, these doses appear justified for a better targeting and could be considered negligible in the context of radiotherapy. On the other hand, the potential impact of these low doses should deserve the consideration of professionals. It appears important therefore to report and consider not only doses in target volumes and in “standard” organs at risk, but also the volume of all tissue receiving low doses of radiation. The recent development of IMRT launches the same issue concerning the effects of low doses of radiation. Indeed, IMRT increases the volume of healthy tissue exposed to radiation. At low dose (<100mGy), many parameters have to be considered for health risk estimations: the induction of genes and activation of proteins, bystander effect, radio-adaptation, the specific low-dose radio-hypersensitivity and individual radiation sensitivity. With the exception of the latter, the contribution of these parameters is generally protective in terms of carcinogenesis. An analysis of secondary cancers arising out of field appears to confirm such notion. The risk of secondary tumours is not well known in these conditions of treatment associating IMRT and IGRT. It is therefore recommended that the dose due to imaging during therapeutic irradiation be reported.

Le texte complet de cet article est disponible en PDF.

Mots clés : CTMI, IGRT, Effet des faibles doses, Volumes tumoraux irradiés, Risque de tumeurs secondaires, Induction de gènes

Keywords : IMRT, IGRT low-dose radiation effect, Irradiated non-tumoral volumes, Secondary tumor risk, Gene induction


Plan


© 2010  Société française de radiothérapie oncologique (SFRO). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 14 - N° 6-7

P. 563-570 - octobre 2010 Retour au numéro
Article précédent Article précédent
  • « Dose-painting » : mythe ou réalité ?
  • S. Supiot, A. Lisbona, F. Paris, D. Azria, P. Fenoglietto
| Article suivant Article suivant
  • De la mutualisation des comités de retour d’expérience (Crex) à l’audit des pratiques cliniques
  • F. Debouck, H.-B. Petit, É. Lartigau

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.