S'abonner

Évaluation de la qualité de l’os dans les allogreffes de main - 02/12/10

Doi : 10.1016/j.main.2010.10.008 
V. Guigal a, , J.-B. Pialat b, N. Vilayphiou c, E. Deshayes d, C. Rizzo a, A. Gazarian a, e
a Département de chirurgie de la main, clinique du parc de Lyon, 155, boulevard Stalingrad, 69006 Lyon, France 
b Service de radiologie, pavillon B, hôpital Édouard-Herriot, 5, place d’Arsonval, 69437 Lyon cedex 03, France 
c Inserm U831, pavillon F, hôpital Édouard-Herriot, 5, place d’Arsonval, 69437 Lyon cedex 03, France 
d Service de médecine nucléaire, hôpital Édouard-Herriot, 5, place d’Arsonval, 69437 Lyon cedex 03, France 
e Service de chirurgie de la transplantation, hôpital Édouard-Herriot, 5, place d’Arsonval, 69437 Lyon cedex 03, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 15
Iconographies 9
Vidéos 0
Autres 0

Résumé

Cinq allogreffes bilatérales d’avant-bras ont été réalisées entre janvier 2000 et juillet 2009 à Lyon (France). Le présent article rapporte une analyse de la qualité, à terme, de l’os apporté par ces allogreffes, chez les quatre premiers patients greffés (trois hommes et une femme). Les techniques retenues dans cette étude ont comporté : l’analyse radioclinique, la scintigraphie osseuse, l’IRM, la densitométrie osseuse, et le scanner périphérique à haute résolution (HR-pQCT). L’histologie osseuse n’a pu être réalisée que chez le premier patient greffé unilatéralement en 1998, qui ne fait pas partie du protocole de recherche clinique, après l’amputation de son membre ; suggérant que l’os se comporte comme un tissu cible possible du rejet chronique mais de manifestation limitée et d’apparition probablement assez tardive. Sur le plan clinique, radiologique et scintigraphique, l’intégration du greffon osseux dans les greffes de mains est macroscopiquement bonne comme en témoigne la consolidation et le comportement général de l’os greffé vis-à-vis de fractures, de l’infection et de la croissance. La scintigraphie ne montre pas de variations sensibles par rapport à celles que l’on peut observer au contact du matériel d’ostéosynthèse ou lors d’autogreffe osseuse. L’IRM ne retrouve aucune anomalie focale ou périostée de l’os greffé. L’ostéodensitométrie ne montre pas de différence significative d’avec l’ostéoporose secondaire que l’on peut observer chez d’autres greffés sous traitement immunosuppresseur, sauf chez le sujet féminin qui en est indemne. L’HR-pQCT montre chez les trois sujets masculins une diminution plus importante de la densité volumétrique pour l’os donneur que pour l’os receveur. Compte tenu du faible nombre de patients concernés par cette étude, ainsi que le différentiel de recul important, les résultats présentés doivent être confirmés par un suivi à plus long terme.

Le texte complet de cet article est disponible en PDF.

Abstract

Five bilateral forearms allograft have been performed between January 2000 and July 2009 in Lyon (France). The first four patients (three males, one female) have been the subject of an assessment of the bone quality of those allografts. The techniques selected for this study were: radioclinical analysis, bone scintigraphy, MRI, bone densitometry and High Resolution peripheral Quantitative Computed Tomography (HR-PQCT). Histology has been performed only on the first patient unilaterally grafted in 1998 who did not take part in this clinical research protocol, after amputation of his rejected graft. On the clinical, radiological and scintigraphical aspects, donor bone integration in hands allograft are good on a macroscopic point of view considering the healing and the general reaction of the bone in situation of fractures, infection and growth. The scintigraphy does not show important variations compared to the ones we can observe on contact with osteosynthesis material or during bone autografts. MRI found neither focal nor periosteal anomaly on grafted bone. The bone densitometry did not show significant difference with secondary osteoporosis one can observe in other grafted patients under immunosuppressive treatment. The HR-PQCT showed for the three males patients, a higher loss in volumetric density, for grafted bone than in the recipient patient control skeleton. Due to the few patients of this series, and the discrepancies in follow-up duration, the presented data have to be confirmed with further studies.

Le texte complet de cet article est disponible en PDF.

Mots clés : Allogreffe de main, Greffe osseuse vascularisée, Évaluation de la qualité osseuse

Keywords : Hand allograft, Vascularized bone graft, Bone quality evaluation


Plan


© 2010  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 29 - N° S1

P. S199-S213 - décembre 2010 Retour au numéro
Article précédent Article précédent
  • Transfert osseux vascularisé d’épiphyse scapulaire
  • A. Brancati, P. Granier, L. Téot
| Article suivant Article suivant
  • Le périoste vascularisé et la reconstruction osseuse
  • D. Moukoko

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.