S'abonner

Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography for the detection of spontaneous third ventriculostomy - 30/04/11

Doi : 10.1016/j.neurad.2010.03.006 
O. Algin a, , B. Hakyemez b, M. Parlak b
a Department of Radiology, Atatürk Training and Research Hospital, Bilkent, Ankara, Turkey 
b Department of Neuroradiology, Uludag University Medical Faculty, Gorukle, Bursa, Turkey 

Corresponding author. Tel.: +0905327064759.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Purpose

To compare the diagnostic efficacies of phase-contrast MRI (PC-MRI) and three-dimensional constructive interference in steady-state (3D-CISS) sequence for the detection of spontaneous third ventriculostomy (STV) on the basis of contrast-enhanced MR cisternography (MRC).

Patients and methods

Eleven obstructive hydrocephalus patients with clinically-radiologically suspected STV and ten controls were examined by PC-MRI, 3D-CISS and MRC. PC-MRI and 3D-CISS sequence were applied to view the third ventricle and basal cisterns. Following injection of 0.5-1ml intrathecal Gd-DTPA injection, postcontrast MRC images were obtained in three planes. Presence of STV was scored as follows: grade 0, no existence of STV; grade 1, STV present. Results of PC-MRI and 3D-CISS were compared with the MRC findings.

Results

In PC-MRI, five patients were assessed as grade 0 and six cases grade 1. As a result of 3D-CISS sequence, eight cases were evaluated as grade 0 and three cases grade 1. Based on MRC, nine cases were assessed as grade 0 and two cases grade 1. False positivity was found in four cases by PC-MRI and in one case by 3D-CISS. The sensitivity, specificity and accuracy of PC-MRI and 3D-CISS sequence regarding demonstration of STV, were 100, 100, 56, 89, 64, and 91% respectively.

Discussion

PC-MRI and 3D-CISS are helpful in confirming the STV. PC-MRI and 3D-CISS should be the first preference. If PC-MRI and 3D-CISS give negative results, then MRC is not required. MRC should be performed on patients who demonstrate suspected STV findings on PC-MRI and 3D-CISS sequences. MRC may prevent false positive results.

Le texte complet de cet article est disponible en PDF.

Keywords : Hydrocephalus, Magnetic resonance imaging, MR cisternography, PC cine MR, Spontaneous third ventriculostomy


Plan


 This study was presented as a scientific presentation at the 48th ASNR Annual Meeting, Boston, Massachusetts, USA, May 17 to 20, 2010.


© 2010  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 38 - N° 2

P. 98-104 - mai 2011 Retour au numéro
Article précédent Article précédent
  • Quantitative proton MRI and MRS of the rat brain with a 3 T clinical MR scanner
  • M. Aradi, R. Steier, P. Bukovics, C. Szalay, G. Perlaki, G. Orsi, J. Pál, J. Janszky, T. Dóczi, A. Schwarcz
| Article suivant Article suivant
  • Early ADC changes in motor structures predict outcome of acute stroke better than lesion volume
  • C. Rosso, O. Colliot, C. Pires, C. Delmaire, R. Valabrègue, S. Crozier, D. Dormont, S. Baillet, Y. Samson, S. Lehéricy

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.