Introduction

Significant femoral neck narrowing following hip resurfacing arthroplasty has been observed. Several factors contributing to the physiopathology of femoral neck narrowing have been suggested. The aim of this study was to evaluate the femoral neck radiographic changes observed after hip resurfacing at a minimum follow-up period of 5years and to determine their causes.

Patients and methods

We conducted a prospective study of 57 hip resurfacing arthroplasties performed in 53 patients (30 men, 23 women) of mean age 49.2years (32–65) at surgery. These patients were clinically reviewed (inguinal pain during walking, WOMAC and UCLA scores) at 2years and radiographically examined at 1, 2 and 5 postoperative years. The accuracy of our computer-aided measurement method was 1mm. Measurement of femoral neck to implant ratio was performed to assess the amount of neck thinning at the femoral neck-implant junction (N/H) and midway between the implant and the inter-trochanteric line (N1/2H) on an AP radiograph. Neck-thinning greater than 10% was considered as significant. Any other radiographic morphologic change in the femoral neck was investigated. Metallic ion concentration in blood was measured. A uni- and multivariate analysis was performed to determine the correlation with radiographic changes.

Results

In one third of the patients, femoral neck narrowing was greater than 1mm at 2 and 5 postoperative years. Such result corresponds to a mean decrease in neck to implant ratio (N/H) of 5.9% (range, 2.3 to 9.4) at 2years and 8.3% (range, 2.5 to 23.8) at 5years. At 5 postoperative years, an overall neck thinning greater than 10% was reported in 3 patients (with a 10- to 17-% increase in femoral neck narrowing between the 2nd and the 5th postoperative year). In one case, neck thinning was associated with fracture of the femoral stem managed with revision surgery during which femoral neck necrosis was confirmed. Neck thinning was, in these cases, circumferential to the neck-implant junction. There was no significant negative impact on clinical scores and no relationship could be established between neck thinning and factors such as BMI or patient activity. Moreover, neck thinning greater than 10% was reported in two cases after 2 postoperative years through the appearance of a localized femoral neck notching which was absent in the postoperative period, secondary to a femoroacetabular impingement.

Discussion–Conclusion

Femoral neck narrowing used to be a common phenomenon after HR when polyethylene acetabular bearings were implanted thus inducing osteolysis secondary to PE wear debris. The incidence of such phenomenon has decreased but still occurs after HR when using a metal-on-metal bearing surface. It has an early occurence but stabilizes after 2 postoperative years. Changes in mechanical stress distribution in the neck region after hip resurfacing have been hypothesized to be a cause of neck thinning. Other aetiologies may be suggested. An overall evolutive femoral neck narrowing after 2 postoperative years should raise the suspicion of necrosis leading to a risk of loosening, fracture or implant failure. Therefore, radiographic monitoring should be conducted. The presence of femoral neck notching secondary to femoroacetabular impingement represents a differential diagnosis which conservative treatment is advocated in the absence of any associated symptoms.

Level of evidence

Level IV, retrospective review.

Le texte complet de cet article est disponible en PDF.

Keywords : Resurfacing, Hip, Femoral neck narrowing, Femoral neck remodeling, Complication, Revision


Plan


© 2011  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 97 - N° 3

P. 229-240 - mai 2011 Retour au numéro
Article précédent Article précédent
  • Contents
| Article suivant Article suivant
  • Is transverse acetabular ligament an anatomical landmark to reliably orient the cup in primary total hip arthroplasty?
  • A. Viste, J. Chouteau, R. Testa, L. Chèze, M.-H. Fessy, B. Moyen

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.