Inondation des capteurs de pression sanguine des générateurs-moniteurs d'hémodialyse - 01/01/05

Doi : 10.1016/j.nephro.2005.03.006 
Philippe Brunet , a, , Gilles Frenkian , b, Anne-Marie Girard , c, Fabrice Gombert , d, Thierry Petitclerc , e, Isabelle Réach , f, Sandrine Colas , g
a Service de néphrologie, assistance-publique-Hôpitaux-de-Marseille, hôpital de la Conception, 147, boulevard Baille, 13385 Marseille cedex 05, France 
b Assistance-publique-Hôpitaux-de-Marseille, hôpital Sainte-Marguerite, 270, boulevard de Sainte-Marguerite, BP 29, 13274 Marseille cedex 09, France 
c FID.-AURA, 26, rue des Peupliers, 75013 Paris, France 
d Clinique E.-Rist, 14, rue Boileau, 75016 Paris, France 
e AURA, 75013 Paris, France 
f Institut mutualiste Montsouris, 42, boulevard Jourdan, 75014 Paris, France 
g Matériovigilance Afssaps, 143-147, boulevard Anatole-France, 93285 Saint-Denis cedex, France 

*Auteur correspondant.

Résumé

La transmission du virus de l'hépatite C dans une unité d'hémodialyse peut se faire de plusieurs façons. Le mode de transmission principal se fait entre les malades traités simultanément dans le même secteur ou dans la même chambre. L'autre mode de transmission virale se fait entre deux malades traités successivement sur le même générateur-moniteur d'hémodialyse et partageant donc le même environnement. L'un des vecteurs de ce dernier mode de transmission pourrait être le système de mesure de pression du circuit sanguin extracorporel. Ce système a fait l'objet en juillet 2004 d'une recommandation de l'agence française de sécurité sanitaire des produits de santé (Afssaps). i) La recommandation rappelle les mesures préventives facultatives que les utilisateurs et les fabricants peuvent appliquer : (a) les fabricants peuvent proposer des systèmes de prise de pression étanches, fondés sur la déformation d'un dispositif ; (b) les utilisateurs peuvent ajouter un second filtre protecteur sur la tubulure extérieure reliant le circuit sanguin au raccord de prise de pression ; (c) les fabricants peuvent ajouter des filtres protecteurs supplémentaires sur les tubulures intérieures du générateur. ii) La recommandation indique les actions à effectuer obligatoirement en cas d'inondation du dernier filtre extérieur : le filtre inondé doit être remplacé et les causes de l'inondation doivent être recherchées et corrigées ; après la séance, l'appareil doit être consigné et examiné par le technicien. Le technicien doit remplacer tous les éléments situés en aval d'un filtre souillé, c'est-à-dire les tubulures, le système de mise à niveau du piège à bulle, et le capteur de pression. Lorsque ces éléments sont protégés par des filtres intérieurs, seuls les tubulures et le premier filtre intérieur non souillé doivent être changés. Les précautions à l'égard des systèmes de prise de pression doivent compléter les précautions d'hygiène standard indispensables dans les unités d'hémodialyse.

Le texte complet de cet article est disponible en PDF.

Abstract

Transmission of hepatitis C virus between hemodialysis patients occurs mainly between the patients treated simultaneously in the same sector or in the same room. The other mode of viral transmission occurs between two patients treated successively with the same hemodialysis generator-monitor and sharing the same environment. One of the vectors of this last mode of transmission could be the contamination of the system of measurement of pressure of the extracorporal blood circuit. In July 2004, the French health products safety agency (Agence française de sécurité sanitaire des produits de santé, Afssaps) published a recommendation on these systems of measurement of pressure. i) The recommendation points out the optional preventive measures that users and manufacturers can carry out: (a) the manufacturers can propose tight systems of measurement of pressure, based on the deformation of a device; (b) the users can add a second protective filter on the external tubing connecting the blood circuit to the machine; (c) the manufacturers can add additional protective filters on the internal tubings of the machine. ii)The recommendation indicates the actions to be carried out obligatorily in the event of backward flow of blood in the last external protective filter: the soiled filter must be replaced and the causes of the backward flow must be analyzed and corrected; after the session, the monitor must be taken out of the unit and checked by a technician. The technician must replace all the elements located downstream from a soiled protective filter: tubings, drip chamber level control system, and pressure transducer. When these elements are protected by internal filters, only tubings and the first internal filter not soiled must be replaced. Precautions with regard to the systems of measurement of pressure must supplement standard precautions of hygiene essential in hemodialysis units.

Le texte complet de cet article est disponible en PDF.

Mots clés : Hémodialyse, Hépatite C, Capteurs de pression, Précautions d'hygiène

Keywords : Hemodialysis, Hepatitis C, Pressure transducers, Precautions of hygiene


Plan


© 2005  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 1 - N° 3

P. 157-160 - juillet 2005 Retour au numéro
Article précédent Article précédent
  • Syndrome néphrotique pur (ou néphrose) corticosensible de l'enfant : Protocole de traitement proposé par la Société de Néphrologie Pédiatrique
  • Étienne Bérard, Michel Broyer, Maud Dehennault, Robert Dumas, Philippe Eckart, Michel Fischbach, Chantal Loirat, Laurence Martinat
| Article suivant Article suivant
  • Le rôle des neutrophiles dans le rejet d'allogreffe
  • Murielle Surquin, Sofia Buonocore, Alain Le Moine, Véronique Flamand, Michel Goldman, Daniel Abramowicz

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.