S'abonner

Nouveautés en curiethérapie gynécologique : nouvelles technologies, curiethérapie pulsée, imagerie, définitions de nouveaux volumes d'intérêt et leur impact sur la dosimétrie : applications dans le cadre d'un STIC - 06/12/06

Doi : 10.1016/j.canrad.2006.06.007 
C. Haie-Meder a, , D. Peiffert b
a Service de curiethérapie, institut Gustave-Roussy, 39, rue Camille-Desmoulins, 94805 Villejuif, France 
b Service de radiothérapie, centre Alexis-Vautrin, avenue de Bourgogne-Brabois, 54511 Vandoeuvre-Lès-Nancy cedex, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 8
Iconographies 2
Vidéos 0
Autres 0

Résumé

La curiethérapie joue un rôle fondamental dans le traitement des patientes atteintes d'un cancer du col utérin de stades I à IV selon la classification de la Figo (Fédération internationale des gynécologues-obstétriciens). Les modalités techniques ont évolué ces dernières décennies : technologie des sources se déplaçant pas à pas, développement des modalités d'imagerie, en particulier l'IRM, systèmes de planification dosimétriques intégrant l'imagerie en trois dimensions. L'imagerie scanographique ou remnographique a contribué à une meilleure connaissance de l'extension tumorale et des organes à risque. Les applicateurs compatibles avec une scanographie ou une IRM ont permis la réalisation d'images avec une amélioration de la définition du volume tumoral par rapport à l'approche traditionnelle. L'introduction de l'approche tridimensionnelle fondée sur l'imagerie implique de nouvelles définitions et un langage commun. En 2000, un groupe de travail a été créé au sein du GEC-ESTRO (Groupe européen de curiethérapie-European Society for Therapeutic Radiology and Oncology) afin de travailler sur la dosimétrie tridimensionnelle fondée sur l'imagerie dans les cancers du col utérin. L'objectif de ce groupe était de décrire une terminologie commune permettant à différentes équipes d'utiliser un langage commun. Des recommandations ont été décrites et proposées sur la base d'expériences cliniques et de concepts dosimétriques provenant de différentes institutions. Deux volumes cibles anatomocliniques (CTVs) ont été décrits en relation avec le risque de récidive locale : un CTV dit à haut risque et un CTV dit à risque intermédiaire. Afin de mieux déterminer le rôle de ces définitions et leur impact potentiel sur l'incidence des complications, un programme de soutien aux techniques innovantes coûteuses (STIC) a été développé en France. L'objectif de ce programme est l'étude de l'incidence à deux ans des complications sévères dans deux populations comparables. Un premier groupe est traité par une technique de curiethérapie pulsée avec applicateur en place permettant une dosimétrie tridimensionnelle sur images scanographiques ou remnographiques avec possibilité d'optimisation, le second groupe est traité à partir de radiographies standard sans délinéation ni possibilité d'optimisation. Il est prévu que chaque groupe inclut 425 patientes. Une évaluation médicoéconomique est également programmée, permettant une évaluation du coût réel de l'approche la plus sophistiquée (curiethérapie pulsée) par comparaison à un système dosimétrique historique.

Le texte complet de cet article est disponible en PDF.

Abstract

Brachytherapy plays a fundamental role in the therapeutic approach of patients with stage I-IV cervical carcinoma. Technical modalities have evolved during the last decades: stepping source technology, imaging modalities development, specially IMN, treatment planning system integrating 3D images. Images from CT-Scan and MRI have contributed to a better knowledge of tumoral extension and critical organs. CT and/or MRI compatible applicators allow a sectional image based approach with a better definition of tumour volume compared to traditional approaches. The introduction of 3D image based approach for GTV and CTV requires new definitions and a common language. In 2000, a working group within GEC-ESTRO was created to support 3D image based 3D treatment planning approach in cervix cancer BT. The task was to determine a common terminology enabling various groups to use a common language. Recommendations were described and proposed based on clinical experience and dosimetric concepts of different institutions. Two CTVs were described en relation to the risk for recurrence: high-risk CTV and intermediate risk CTV. In order to better define the role of such definitions and their potential impact on the complication incidence in patients with cervical cancer, a special French programme was developed. The aim of this programme is to study the incidence of the severe 2-year complication rate in two comparable patient populations: one population is treated using PDR brachytherapy with CT-Scan or MRI with the applicators in place allowing a 3D dosimetry with optimization, the second population is treated using standard X-rays radiographs without any delineation of the target nor optimisation. Each population arm includes 425 patients. A medicoeconomic assessment is performed, allowing a real cost of the most sophisticated approach compared to a historical dosimetric system.

Le texte complet de cet article est disponible en PDF.

Mots clés : Cancer du col utérin, Curiethérapie, Curiethérapie pulsée, STIC, Dosimétrie tridimensionnelle, Optimisation

Keywords : Cervix cancer, Brachytherapy, PDR, Three-dimensional dosimetry, Optimization


Plan


© 2006  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 10 - N° 6-7

P. 402-409 - novembre 2006 Retour au numéro
Article précédent Article précédent
  • Dispositifs de repositionnement prostatique sous l'accélérateur linéaire
  • R. de Crevoisier, J.-L. Lagrange, T. Messai, B. M'Barek, D. Lefkopoulos
| Article suivant Article suivant
  • Approche conservatrice et fonctionnelle dans les sarcomes des tissus mous des membres : place de la radiothérapie
  • Y. Milbéo, G. Kantor, P. Lagarde, E. Stoeckle, A. Duparc, L. Thomas, B.-N. Bui

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.