Fiabilité et survie du cathéter artériel: réponse dynamique optimale - 12/03/07

Doi : 10.1016/j.annfar.2006.11.008 
M. Riachy a, , E. Riachy a, G. Sleilaty b, G. Dabar a, A. Yazigi c, G. Khayat a
a Service de pneumologie et de réanimation médicale, Hôtel-Dieu-de-France, rue Alfred-Naccache, Achrafieh, Beyrouth, Liban 
b Service de chirurgie cardiothoracique, Hôtel-Dieu-de-France, rue Alfred-Naccache, Achrafieh, Beyrouth, Liban 
c Service d'anesthésie, Hôtel-Dieu-de-France, rue Alfred-Naccache, Achrafieh, Beyrouth, Liban 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 6
Iconographies 3
Vidéos 0
Autres 0

Résumé

Objectifs

La pression artérielle est l'un des paramètres hémodynamiques les plus critiques en réanimation. Le but de cette étude est d'évaluer la fiabilité de la mesure de cette pression en évaluant la réponse dynamique du cathéter artériel au cours du temps et ceci avant l'occlusion totale du cathéter.

Type d'étude

Étude prospective observationnelle.

Patients et méthodes

Le coefficient d'amortissement (ξ) et la fréquence naturelle (Fn) du système du cathéter artériel ont été mesurés in vivo. La mesure de ces constantes physiques est effectuée à la mise du cathéter (T0) puis toutes les 12 heures jusqu'à l'ablation du cathéter (T19) par le test de rinçage rapide chez 61 patients. Les mesures de la pression artérielle invasive (cathéter artériel) et non invasive (oscillométrique) ont été comparées toutes les 12 heures tant que le cathéter est en place.

Résultats

Tout au long de la période étudiée (240 heures), les mesures de la pression artérielle moyenne par les méthodes invasive et non invasive ont été très concordantes (coefficient>0,7). Seulement 3,39% des cathéters avaient leurs constantes physiques (ξ et Fn) dans la zone optimale à T0 versus 66,67% à T19. La durée maximale d'utilisation du cathéter était fortement corrélée au bon fonctionnement du cathéter (r=0,739; p<10-4). L'analyse multivariée par un modèle de Cox montre que la distance au pli (RR=2,07±0,73; p=0,039) et le nombre de prélèvements sanguins (RR=0,796±0,042; p<10-4) ont influencé le bon fonctionnement du cathéter.

Conclusion

La mesure de la pression artérielle invasive est fiable pendant une longue durée, dépassant dix jours, en particulier lorsque cette technique sert à mesurer la pression artérielle moyenne. Chaque fois que la distance entre le site d'insertion du cathéter s'éloigne de 1 cm par rapport au pli de l'articulation radiocarpienne ou au pli de l'aine, le risque de dysfonctionnement du cathéter était double; et à chaque prélèvement de sang par le cathéter, ce risque était diminué de 20%.

Le texte complet de cet article est disponible en PDF.

Abstract

Objectives

Blood pressure is one of the most critical haemodynamic parameter in the intensive care unit (ICU). The measurement relies mainly on invasive methods (arterial lines) but also on noninvasive methods (Oscillometric and Manual). It is crucial to be instantaneous and accurate to adapt any decision making plan. The aim of this study is to evaluate the reliability of this measure given by an arterial catheter over time. This can determine the maintenance of catheter patency before clinical total occlusion.

Study design

Observational prospective study.

Patients and methods

Damping coefficient (ξ) and natural frequency (Fn) of the arterial catheter system are studied in vivo each 12 hours by a fast flush test (FFT) in 61 patients. The measurements of the arterial blood pressure invasively (arterial catheter method) and non invasively (oscillometric method) are compared each 12 hours until the catheter is removed.

Results

All over the study period for each catheter (till 240 hours), the mean arterial blood pressure measurements given by either the catheter method or the oscillometric method were very concordant (coefficient>0.7). Only 3.39% of the catheters had their physical characteristics (ξ and Fn) in the optimal zone at T0; reaching 66.67% at T19. The maximal inserted time was highly correlated with a good operating catheter (R=0.739; P<10-4).

Conclusion

The measure of the arterial blood pressure invasively can still be reliable for a long period of time (10 days), as long as the catheter is inserted, especially when the mean arterial pressure is considered. Each time the distance of the catheter insertion site moves away 1 cm from the radiocarpal joint or the groin, the risk of troubleshooting is doubled; on each blood sample from the catheter, this risk is reduced by 20%.

Le texte complet de cet article est disponible en PDF.

Mots clés : Occlusion du cathéter artériel, Thrombose, Coefficient d'amortissement, Fréquence naturelle

Keywords : Occlusion of arterial catheter, Thrombosis, Damping coefficient, Natural Frequency


Plan


© 2006  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 26 - N° 2

P. 119-124 - février 2007 Retour au numéro
Article précédent Article précédent
  • L'entropie: un moyen d'apprécier le défaut d'analgésie?
  • E. Dierckens, M. Fleyfel, E. Robin, A. Legrand, M. Borel, L. Gambier, B. Vallet, G. Lebuffe
| Article suivant Article suivant
  • Évaluation de l'analgésie postopératoire par bloc continu iliofascial après chirurgie pour remplacement de prothèse totale de hanche: étude pilote
  • E. Pavy, V. Compère, V. Fourdrinier, C.-E. Beghin, F. Dujardin, B. Dureuil

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.