S'abonner

Mapping structural to functional damage in glaucoma with standard automated perimetry and confocal scanning laser ophthalmoscopy - 09/09/11

Doi : 10.1016/S0002-9394(99)80183-4 
Alfonso Anton, MD, Noriko Yamagishi, PhD, Linda Zangwill, PhD, Pamela A. Sample, PhD, Robert N. Weinreb, MD
 From the Glaucoma Center and Research Laboratories, University of California, San Diego, La Jolla, California, USA 

**Correspondence to Robert N. Weinreb, MD, Shiley Eye Center, University of California, San Diego, 9500 Gilman Dr, La Jolla, CA 92093-0946; fax: (619) 534-1625.

Abstract

Purpose

To develop a quantitative method for analysis of the topographic relationship between structural and functional damage in patients with glaucoma.

Methods

We studied 26 patients with primary open-angle glaucoma, focal optic disk damage, and focal visual field loss. The visual field was evaluated with automated perimetry, and the optic disk topography was assessed with a confocal scanning laser ophthalmoscope. Topographic measurements were calculated in 10-degree sectors and compared with a normative database (n = 52). The topographic relationship of structural damage and functional loss was analyzed.

Results

Rim area ratio was defined as the ratio of rim area in each 10-degree sector divided by the total rim area. This ratio resulted in the identification of one (46%) or more (54%) clusters of optic disk sectors as outside normal limits in all 26 patients (12 and 14 patients, respectively). Twenty-two patients (84%) with superior hemifield sensitivity loss tended to have inferior rim defects, and vice versa. Nasal visual field defects close to the horizontal midline were matched with damaged rim areas close to the vertical midline.

Conclusions

This mapping method allows an objective and quantitative evaluation of the optic disk and visual field in patients with glaucoma and focal damage. Although the topographic relationship between structure and function is characterized by considerable interindividual variability, the identification of certain patterns may be useful to aid in the evaluation of glaucomatous damage.

Le texte complet de cet article est disponible en PDF.

* Supported in part by National Eye Institute grants EY11008 (Dr Zangwill), EY08208 (Dr Sample), and EY11158 (Dr Weinreb); grant 95/5039 from the Fondo de Investigaciones Sanitarias, Madrid, Spain (Dr Anton); a grant from the Foundation for Eye Research, Rancho Santa Fe, California (Dr Anton); and an unrestricted grant from Research to Prevent Blindness, Inc, New York, New York.


© 1998  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 125 - N° 4

P. 436-446 - avril 1998 Retour au numéro
Article précédent Article précédent
  • Liquefied aftercataract: A complication of continuous curvilinear capsulorhexis and intraocular lens implantation in the lens capsule
  • Kensaku Miyake, Ichiro Ota, Sampei Miyake, Masayuki Horiguchi
| Article suivant Article suivant
  • Confocal tomographic angiography of the optic nerve head in patients with glaucoma
  • Shlomo Melamed, Hana Levkovitch-Verbin, Sara Krupsky, Giora Treister

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.