Rotational positioning of the tibial tray in total knee arthroplasty: A CT evaluation - 26/10/11

Doi : 10.1016/j.otsr.2011.05.006 
J. Berhouet a, b, , P. Beaufils a, P. Boisrenoult a, D. Frasca c, N. Pujol a
a Versailles-Saint-Quentin University, André-Mignot Hospital, Versailles Hospital Center, Department of Orthopaedics and Trauma, 177, rue de Versailles, 78157 Le-Chesnay, France 
b François-Rabelais University of Tours, Trousseau University Regional Hospital Center, Department of Orthopaedics and Trauma, 2A, avenue de la République, 37170 Chambray-les-Tours, France 
c Poitiers University, La-Milétrie University Hospital Center, Department of Anaesthesia and Intensive Care, 2, rue de La-Milétrie, 86021 Poitiers, France 

Corresponding author. Tel.: +33 2 47 47 47 47; fax: +33 2 47 47 59 12.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Introduction

Various surgical techniques have been described to set the rotational alignment of the tibial baseplate during total knee arthroplasty. The self-positioning method (“self-adjustment”) aligns the tibial implant according to the rotational alignment of the femoral component which is used as a reference after performing repeated knee flexion/extension cycles. Postoperative computed tomography scanning produces accurate measurements of the tibial baseplate rotational alignment with respect to the femoral component.

Hypothesis

The rotational positioning of the tibial baseplate matches the rotation of the femoral component with parallel alignment to the prosthetic posterior bicondylar axis.

Patients and methods

A 3-month follow-up CT scan was carried out after primary total knee arthroplasty implanted in osteoarthritic patients with a mean 7.8° varus deformity of the knee in 50 cases and a mean 8.7° valgus deformity of the knee in 44 cases. The NexGen LPS Flex (Zimmer) fixed-bearing knee prosthesis was used in all cases. An independant examiner (not part of the operating team) measured different variables: the angle between the anatomic transepicondylar axis and the posterior bicondylar axis of the femoral prosthesis (prosthetic posterior condylar angle), the angle between the posterior bicondylar axis and the posterior marginal axis of the tibial prosthesis, the angle between the posterior marginal axis of the tibial prosthesis and the posterior marginal axis of the tibial bone and finally the angle between the anatomic transepicondylar axis and the posterior marginal axis of the tibial prosthesis.

Results

For the genu varum and genu valgum subgroups, the mean posterior condylar axis of the femoral prosthesis was 3.1° (SD: 1.91; extremes 0° to 17.5°) and 4.7° (SD: 2.7; extremes 0° to 11°) respectively. The tibial baseplate was placed in external rotation with respect to the femoral component: 0.7° (SD : 4.45; extremes –9.5° to 9.8°) and 0.9° (SD: 4.53; extremes –10.8° to 9.5°), but also to the native tibia: 6.1° (SD: 5.85; extremes –4.6° to 22.5°) and 12.5° (SD: 8.6; extremes –10° to 28.9°). The tibial component was placed in internal rotation relative to the anatomic transepicondylar axis: 1.9° (SD : 4.93; extremes –13.6° to 7°) and 3° (SD : 4.38; extremes –16.2° to 4.8°).

Discussion

The tibial component is aligned parallel to the femoral component whatever the initial frontal deformity (P0.7). However, a difference was observed between the rotational alignment of the tibial baseplate and the native tibia depending on the initial deformity and could be attributed to the morphological variations of the bony tibial plateau in case of genu valgum.

Conclusion

The self-positioning method is a reproducible option when using this type of implant since it allows the tibial component to be positioned parallel to the posterior border of the femur.

Level of evidence

Level III. Observational prospective study.

Le texte complet de cet article est disponible en PDF.

Keywords : Knee, Total knee arthroplasty, Tibial rotation, Computed tomography scanning (CT scanning), Tibial component positioning


Plan


© 2011  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 97 - N° 7

P. 699-704 - novembre 2011 Retour au numéro
Article précédent Article précédent
  • Interprosthetic femoral fractures: Analysis of 14 cases. Proposal for an additional grade in the Vancouver and SoFCOT classifications
  • M. Soenen, H. Migaud, F. Bonnomet, J. Girard, H. Mathevon, M. Ehlinger
| Article suivant Article suivant
  • Opening wedge high tibial osteotomy performed without filling the defect but with locking plate fixation (TomoFix™) and early weight-bearing: Prospective evaluation of bone union, precision and maintenance of correction in 51 cases
  • T. Brosset, G. Pasquier, H. Migaud, F. Gougeon

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.