S'abonner

Tomographie par émission de positons au (18F)-fluorodésoxyglucose dans les cancers du col utérin : évaluation ganglionnaire et valeur pronostique/prédictive des données de la tumeur primitive - 06/12/11

Doi : 10.1016/j.canrad.2011.05.013 
J. Leseur a, , A. Devillers b, D. Williaume a, E. Le Prisé a, C. Fougerou c, d, e, C. Bouriel f, J. Levêque g, E. Monpetit h, J. Blanchot i, R. de Crevoisier a, E. Garin b
a Département des radiations, centre Eugène-Marquis, rue de la Bataille-Flandres-Dunkerque, CS 44229, 35042 Rennes cedex, France 
b Service de médecine nucléaire, centre Eugène-Marquis, rue de la Bataille-Flandres-Dunkerque, CS 44229, 35042 Rennes cedex, France 
c Service de pharmacologie, CHU de Rennes, 35033 Rennes cedex 09, France 
d Inserm 0203, centre d’investigations cliniques, CHU de Rennes, 35033 Rennes cedex 09, France 
e Université de Rennes 1, CS 46510, 35065 Rennes cedex, France 
f Service de radiologie, centre Eugène-Marquis, rue de la Bataille-Flandres-Dunkerque, CS 44229, 35042 Rennes cedex, France 
g Département de gynécologie et obstétrique, CHU Anne-de-Bretagne, 16, boulevard de Bulgarie, 35203 Rennes cedex 2, France 
h Département des radiations, clinique Océane, 11, rue du Docteur-Joseph-Audic, Le Ténénio, BP 50020, 56001 Vannes cedex, France 
i Département de gynécologie et obstétrique, clinique mutualiste La Sagesse, 4, place Saint-Guénolé, CS 44345, 35043 Rennes cedex, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 10
Iconographies 4
Vidéos 0
Autres 0

Résumé

Objectifs

Évaluer dans le bilan initial des cancers du col utérin : (a) la performance de la tomographie par émission de positons (TEP) au (18F)-fluorodésoxyglucose dans la détection ganglionnaire ; (b) la valeur pronostique et prédictive de paramètres quantitatifs provenant de la tumeur cervicale définis par TEP.

Patientes et méthodes

Étude rétrospective incluant 90 patientes traitées pour un cancer du col utérin évalué initialement par IRM et TEP, analysant les performances de la TEP pour détecter la tumeur cervicale et les ganglions (par rapport au curage) en termes de sensibilité, spécificité, valeurs prédictives positive et négative. Les paramètres tumoraux analysés sur la TEP étaient : la standard uptake value maximale (SUVmax), le volume et le diamètre maximal. Les valeurs pronostique et prédictive de ces paramètres ont été recherchées. La réponse tumorale a été évaluée sur pièce opératoire.

Résultats

La TEP détectait la tumeur cervicale avec une sensibilité de 97 % (SUVmax moyenne=15,8 ; volume moyen=27mm3 ; diamètre maximal moyen=47mm). En ce qui concerne l’évaluation ganglionnaire, les valeurs de sensibilité, spécificité, valeur prédictive positive et valeur prédictive négative étaient de : 86, 56, 69 et 78 % dans le pelvis et : 90, 67, 50 et 95 % dans la région lombo-aortique. La SUVmax était corrélé avec la réponse histologique (p=0,04). Le taux de réponse histologique complète était significativement plus bas pour une SUVmax tumorale de plus de 10,9 (p=0,017). Le diamètre maximal et la réponse histologique avaient un impact sur la survie sans récidive et sur la survie globale en analyse multifactorielle (p<0,05).

Conclusion

La TEP présente une sensibilité élevée dans la détection ganglionnaire pelvienne et lombo-aortique. Certains paramètres ont, par ailleurs, un intérêt pronostique et prédictif en ce qui concerne la tumeur cervicale.

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose

In cervix carcinoma: (a) to evaluate the ability of (18F)-fluorodeoxyglucose (FDG) positron emission tomography (PET) in the lymph node detection; (b) to investigate the prognostic and predictive value of the primary cervical PET parameters.

Patients and methods

Ninety patients treated for cervix carcinoma and evaluated initially by MRI and FGD PET were included. The performances of FDG-PET for lymph node detection (relatively to the lymph node dissection) have been described (sensitivity, specificity, positive predictive value and negative predictive value). PET tumour parameters analyzed were: maximum standard uptake value (SUVmax), the volume and the maximum diameter. The prognostic and predictive values of these parameters were investigated. The tumour response was evaluated on surgical specimens.

Results

PET detected the cervical tumour with a sensitivity of 97% (mean values: SUVmax=15.8, volume=27mm3, maximum diameter=47). For the detection of the lymph nodes, the values of sensibility, specificity, positive predictive value and negative predictive value were: 86, 56, 69 and 78% in the pelvic, and 90, 67, 50 and 95% for the para-aortic area, respectively. The SUVmax was correlated with histologic response (P=0.04). The frequency of partial histological response was significantly higher for tumour SUVmax>10.9 (P=0.017). The maximum PET diameter and pathologic response had an impact on disease-free survival and overall survival in multivariate analysis (P<0.05).

Conclusion

PET has high sensitivity in detecting pelvic and para-aortic lymph nodes. Some primary cervical tumour PET parameters are useful as prognostic and predictive factors.

Le texte complet de cet article est disponible en PDF.

Mots clés : TEP, (18F)-FDG, Cancer du col utérin, Pronostic

Keywords : PET, (18F)-FDG, Cervix cancer, Prognostic


Plan


© 2011  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 15 - N° 8

P. 699-708 - décembre 2011 Retour au numéro
Article précédent Article précédent
  • De la radiothérapie guidée par l’image à la radiothérapie guidée par la dose
  • G. Cazoulat, M. Lesaunier, A. Simon, P. Haigron, O. Acosta, G. Louvel, C. Lafond, E. Chajon, J. Leseur, R. de Crevoisier
| Article suivant Article suivant
  • Optimisation de l’« involved-node radiotherapy » par l’utilisation de la modulation d’intensité dans le lymphome hodgkinien localisé : expérience de l’institut Gustave-Roussy
  • A. Paumier, W. Khodari, A. Beaudre, M. Ghalibafian, P. Blanchard, H. Al Hamokles, M. Bhari, N. Lessard, T. Girinsky

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.