S'abonner

A well-fixed femoral stem facing a failed acetabular component: To exchange or not? A 5- to 15-year follow-up study - 07/02/12

Doi : 10.1016/j.otsr.2011.08.014 
E. de Thomasson , C. Conso, C. Mazel
Montsouris Mutual Hospital Institute, 42, boulevard Jourdan, 75014 Paris, France 

Corresponding author. Tel.: +33 1 56 61 64 03; fax: +33 1 56 61 64 38.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Introduction

There is no consensus about the necessity of exchanging a stable femoral component during revision total hip arthroplasty (RTHA) when only the acetabular component requires replacement. Sparing the femoral component reduces morbidity, but can make acetabular replacement technically more difficult. Moreover, the outcome of the retained femoral component is also a question, especially with older implants.

Hypothesis

Isolated acetabular component RTHA results in lower surgical morbidity, and does not increase the risk of later femoral complications.

Patients and methods

Eighty-nine patients, mean age 68, underwent surgery (anterior approach on traction table) for isolated acetabular component revision between 1994 and 2005. The femoral component had been implanted a mean 10.5 years before revision.

Results

Fifteen patients died, mean age 84.5. Eleven patients, mean age 81.3, were lost to follow-up and four underwent revision due to a subsequent infection (range 14 months – 11 years). Fifty-nine patients were evaluated after a mean 8.6 years (range 4 – 15 years). At follow-up the mean Harris score was 89.2 [IC=6.89; 44 – 100] and the mean Merle d’Aubigné score was 15.3 [IC=1.57; 11 – 18]. Five patients (5.6%) underwent surgery again due to postoperative dislocation. Six patients underwent surgery for recurrent acetabular loosening due to allograft resorption. The size of the bone defects did not increase the risk of these failures (P>0.6). Fractures occurred in two femoral components 6 and 9 years after revision. Polyethylene wear occurred in three patients requiring two repeat revisions at 6 and 7 years. In both cases the femoral component included a titanium head, which caused the wear. Implant survival at 8.6 years was 85.16±0.117% all causes of revision combined, 88.47±0.113% if infectious causes were excluded and 93.6±0.07% if only cases of acetabular component failure were taken into account.

Conclusion

Intermediate term outcomes are satisfactory if stable femoral components are retained. Nevertheless, this procedure should be performed in situations of correctly oriented modular components. In single piece (monoblock) femoral implants, or in implants with a history of failure, this technique should be restricted to elderly and/or fragile patients.

Level of evidence

Level IV, Retrospective study.

Le texte complet de cet article est disponible en PDF.

Keywords : Acetabular, Revision, Arthroplasty, Morbidity, Hip


Plan


© 2012  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 98 - N° 1

P. 24-29 - février 2012 Retour au numéro
Article précédent Article précédent
  • Clinical evaluation of hip joint rotation range of motion in adults
  • P. Kouyoumdjian, R. Coulomb, T. Sanchez, G. Asencio
| Article suivant Article suivant
  • Surgery for femoroacetabular impingement using a minimally invasive anterolateral approach: Analysis of 118 cases at 2.2-year follow-up
  • P. Chiron, A. Espié, N. Reina, E. Cavaignac, F. Molinier, J.-M. Laffosse

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.