Reproducibility of an optical measurement system for the clinical evaluation of active knee rotation in weight-bearing, healthy subjects - 27/03/12

Doi : 10.1016/j.otsr.2011.08.017 
R. Testa a, b, c, , J. Chouteau a, b, c, d, A. Viste a, b, c, d, L. Cheze a, b, c, M.-H. Fessy a, b, c, d, B. Moyen a, b, c, d
a Lyon University, 69000, Lyon, France 
b IFSTTAR, UMR T9406, LBMC, Bron, France 
c Lyon 1 University, Villeurbanne, France 
d Orthopaedic Surgery Department, South Lyon-Hospital Center, 69495 Pierre-Bénite cedex, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Introduction

A knee is typically evaluated passively by a clinician during an office visit, without using dedicated measurement tools. When the knee is evaluated with the patient standing and actively participating in the movement, the results will differ than when the knee is passively moved through its range-of-motion by the surgeon. If a precise measurement system was available, it could provide additional information to the clinician during this evaluation.

Hypothesis

The goal of this study was to verify the reproducibility of a fast, flexible optical measurement system to measure rotational knee laxity during weight-bearing.

Material and methods

Two passive reflective targets were placed on the legs of 11 subjects to monitor femur and tibia displacements in three dimensions. Subjects performed internal and external rotation movements with the knee extended or flexed 30°. During each movement, seven variables were measured: internal rotation, external rotation and overall laxity in extension and 30° flexion, along with neutral rotation value in 30° flexion. Measurement accuracy was also assessed and the right and left knees were compared. Reproducibility was assessed over two measurements sessions.

Results

The calculated intra-class correlation coefficient (ICC) for reproducibility was above 0.9 for five of the seven variables measured. The calculated ICC for the right/left comparison was above 0.75 for five of the seven variables measured.

Discussion

These results confirmed that the proposed system provides reproducible measurements. Our right/left comparison results were consistent with the published literature. This system is fast, reproducible and flexible, which makes it suitable for assessing various weight-bearing movements during clinical evaluations.

Level of evidence

Level III, experimental study.

Le texte complet de cet article est disponible en PDF.

Keywords : Knee, Rotation, Laxity, Measurement system, Optical, Kinematics, Gait analysis


Plan


© 2012  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 98 - N° 2

P. 159-166 - avril 2012 Retour au numéro
Article précédent Article précédent
  • Accuracy of the preoperative planning for cementless total hip arthroplasty. A randomised comparison between three-dimensional computerised planning and conventional templating
  • E. Sariali, R. Mauprivez, F. Khiami, H. Pascal-Mousselard, Y. Catonné
| Article suivant Article suivant
  • Medial facet patelloplasty in patellar instability associated with patellofemoral dysplasia: A report of 26 cases
  • D. Saragaglia, R. Mader, M. Blaysat, N. Mercier

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.