S'abonner

Does fibrin sealant use in total knee replacement reduce transfusion rates? A non-randomised comparative study - 27/03/12

Doi : 10.1016/j.otsr.2011.10.012 
P. Massin , C. Scemama, C. Jeanrot, P. Boyer
Department of Orthopaedic Surgery, Bichat Claude-Bernard Teaching Hospital Center, Paris Diderot University, 46, rue Henri-Huchard, 75877 Paris cedex 18, France 

Corresponding author. Tel.: +33 1 40 24 75 03; fax: +33 1 40 25 71 84.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Background

Studies assessing fibrin sealants use during total knee replacement (TKR) have produced inconsistent results. We evaluated fibrin sealant therapy in TKR procedures performed without tourniquet and without postoperative drains.

Hypothesis

Use of a fibrin sealant during TKR decreases calculated total blood loss, thereby diminishing blood transfusion requirements and costs.

Patients and methods

We studied 62 patients with primary knee osteoarthritis who underwent TKR by the same surgeon between September 2009 and December 2010. Fibrin sealant was used only in the last 31 patients, who were compared to the first 31 patients regarding calculated total blood loss, blood transfusion rate, and mean number of red-blood-cell units used per patient. Costs were compared in the two groups.

Results

In the control group, mean total blood loss calculated using the method of Gross was 1.3±0.6L, 48% of patients required blood transfusions, and the mean number of units per patient was 0.9±1. In the fibrin-sealant group, 29% of patients required blood transfusions and the mean number of units was 0.6±0.9. The between-group differences in favour of the fibrin-sealant group were not statistically significant. In each group, compared with patients not requiring blood transfusions, patients needing transfusions had significantly lower starting preoperative haemoglobin values and a significantly greater positive difference between the calculated total blood loss and the maximum allowable blood loss. In the test group, the cost of the 31 units of fibrin sealant was 9743€ and the cost reduction due to using 11 fewer red-blood-cell units was only 3484€. Hospital stay was not significantly shorter in any of the two groups.

Discussion

Blood transfusion minimisation during TKR should rely chiefly on correcting preoperative anaemia and optimizing transfusion decisions based on the difference between the total blood loss and the maximum allowable blood loss. Fibrin sealant did not significantly diminish transfusion requirements in our study. Randomised studies in larger patient populations are needed. The cost of fibrin sealant may exceed the expected cost savings in relation with decreased blood transfusion requirements.

Level of evidence

Level III (before-after therapeutic study).

Le texte complet de cet article est disponible en PDF.

Keywords : Total knee replacement, Blood loss, Fibrin sealant


Plan


© 2012  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 98 - N° 2

P. 180-185 - avril 2012 Retour au numéro
Article précédent Article précédent
  • Reliability of locked plating in tibial plateau fractures with a medial component
  • M. Ehlinger, M. Rahme, B.-K. Moor, A. Di Marco, D. Brinkert, P. Adam, F. Bonnomet
| Article suivant Article suivant
  • Oral thromboprophylaxis following total hip replacement: The issue of compliance
  • B. Lebel, M. Malherbe, S. Gouzy, J.-J. Parienti, J.-J. Dutheil, M.-T. Barrellier, C. Vielpeau

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.