Développement de l’appareil Papillon 50™ et de ses applicateurs pour la radiothérapie 50 kV des cancers du rectum et de la peau - 28/03/12

Development of a new Papillon 50™ machine with dedicated applicators used for 50 kV X-ray radiotherapy of rectal and skin cancers

Doi : 10.1016/j.irbm.2012.01.003 
J.-P. Gérard a, , S. Marcie b, O. Croce c, S. Hachem c, R. Trimaud b, J.-M. Bordy d, M. Denoziere d, A. Courdi a, K. Benezery a, J.-M. Hannoun Levi a, N. Barbet e
a Centre Antoine-Lacassagne, laboratoire de physique, université de Nice, laboratoire LNH Becquerel Saclay, centre de radiothérapie, Macon, 33, avenue de Valombrose, 06189 Nice cedex, France 
b Centre Antoine-Lacassagne, laboratoire de physique, université de Nice, 33, avenue de Valombrose, 06189 Nice cedex, France 
c Laboratoire de physique-médicale, université de Nice, Nice, France 
d Centre de radiothérapie, laboratoire LNH Becquerel-Saclay, Macon, France 
e Centre de radiothérapie, Macon, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 8
Iconographies 8
Vidéos 0
Autres 0

Résumé

Objectifs

La radiothérapie de contact 50kV (CXRT) a fait la preuve de son service médical rendu pour les cancers du rectum et de la peau. Le but de cette recherche technologique est de développer un nouvel appareil (Papillon 50 tm) (P50) et ses applicateurs pour remplacer l’appareil Philips RT 50 arrivé à obsolescence.

Matériels et méthodes

Les caractéristiques du faisceau de rayons X produit par le P 50 fabriqué en Angleterre ont été étudiés à l’aide de spectromètre, chambre d’ionisation, films Gafchromic et calcul Monte Carlo. Des applicateurs ont été conçus et réalisés à Nice. Les données dosimétriques de chaque applicateur ont été évaluées. Des protocoles d’irradiation validés ont été utilisés pour traiter les patients.

Résultats

Entre septembre 2009 et novembre 2011, le bon fonctionnement du P50 a pu être vérifié avec un débit de dose voisin de 15Gy/min selon les applicateurs. Les distributions de doses obtenues ont été conformes aux objectifs. Les résultats observés sur 62 patients traités au centre Antoine-Lacassagne ont confirmé l’efficacité de cette technique et sa bonne tolérance. Des résultats identiques ont été obtenus au centre de Clatterbridge dans les cancers du rectum.

Discussion

Les résultats obtenus sont très encourageants et doivent déboucher sur une commercialisation internationale de plusieurs appareils P50 et la mise au point de nouveaux appareils (Papillon Plus) destinés à la radiothérapie peropératoire et du fond vaginal.

Conclusion

Cette expérience de recherche et développement bien encadrée par le programme TecSan montre que cette dynamique d’innovation technologique en radiothérapie doit être encouragée et développée.

Le texte complet de cet article est disponible en PDF.

Abstract

Objective

Contact X-Ray 50kV (CXRT) has proven its efficiency to treat rectum and skin cancers. The goal of this technological research was to design and produce a new CXRT machine with dedicated applicators to replace the Philips unit not any more manufactured.

Materials and methods

The P50 was assembled in UK and the characteristics of the machine were evaluated with spectrometers, ions chambers, Gafchromic films and Monte Carlo code. The applicators were designed and manufactured in Nice. Dosimetric data were measured for each applicator. Validated protocols were used to treat patients.

Results

Between September 2009 and November 2011, the performances of the P50 was judged satisfactory with a dose rate close to 15Gy/min depending on the applicator. The dose distribution was according to objectives. Clinical results achieved in 62 patients treated in centre Antoine-Lacassagne for rectum, skin or eyelid cancers confirmed the efficiency and good tolerance of CXRT. Similar results in rectal cancer were observed in Clatterbridge with 120 rectal cancers treated with P50.

Discussion

These results are encouraging and should contribute to the international dissemination of CXRT. New machine (Papillon Plus) should be designed and produced for intraoperative irradiation and treatment of vaginal vault.

Conclusion

This experience of research and development well structured within the frame of TecSan project should be encouraged further to facilitate technological innovation in the field of radiotherapy.

Le texte complet de cet article est disponible en PDF.

Plan


© 2012  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 33 - N° 2

P. 109-116 - avril 2012 Retour au numéro
Article précédent Article précédent
  • Imagerie 3D fonctionnelle de l’articulation de la hanche pour la prévention, le diagnostic, la planification et le suivi chirurgical
  • M. Delplanque, M. de la Simone, V. Burdin, W. Skalli, V. Pomero, A. Brusson, J.Y. Lazennec
| Article suivant Article suivant
  • A passive pressure sensor for continuously measuring the intraocular pressure in glaucomatous patients
  • P. Auvray, L. Rousseau, G. Lissorgues, F. Soulier, O. Potin, S. Bernard, F. Dieuleveult, E. Scorsone, P. Bergonzo, L. Chicaud, S. Picaud, J.A. Sahel

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.