S'abonner

Planification selon la position moyenne du cycle respiratoire : modèle de planification optimale pour une distribution de dose dans les tumeurs pulmonaires - 01/04/12

Doi : 10.1016/j.canrad.2011.07.246 
M. Benchalal a, , G. Cazoulat b, c, J. Bellec d, J. Leseur a, E. Chajon a, P. Haigron b, c, H. Léna e, R. de Crevoisier a, b, c, A. Simon b, c
a Département de radiothérapie, centre Eugène-Marquis, avenue de la Bataille-Flandres-Dunkerque, 35042 Rennes cedex, France 
b Inserm U642, campus de Beaulieu, 263, avenue du Général-Leclerc, 35042 Rennes cedex, France 
c Laboratoire du traitement du signal et de l’image (LTSI), université de Rennes-1, campus de Beaulieu, 263, avenue du Général-Leclerc, 35042 Rennes cedex, France 
d Départment de radiophysique, centre Eugène-Marquis, avenue de la Bataille-Flandres-Dunkerque, 35042 Rennes cedex, France 
e Service de pneumologie, hôpital Pontchaillou, CHU Pontchaillou, 2, rue Henri-Le-Guilloux, 35033 Rennes cedex, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 9
Iconographies 8
Vidéos 0
Autres 0

Résumé

Objectifs de l’étude

La distribution de dose dans une tumeur pulmonaire, calculée lors d’une planification tridimensionnelle est par nature imprécise en raison des mouvements liés à la respiration. La possibilité de réaliser une scanographie intégrant ces mouvements (quadrimensionnelle) permet de connaître, d’une part, l’amplitude et la direction du déplacement de la tumeur (volume cible interne [ITV]), d’autre part, la position moyenne géométrique du barycentre de la tumeur et la position moyenne du cycle respiratoire ou mid-ventilation position (MVP).

Patient et méthodes

À partir du concept de volume cible interne et de position moyenne cycle respiratoire, nous avons, pour un patient traité dans notre établissement pour une tumeur pulmonaire, calculé une distribution de dose en trois dimensions et une distribution de dose en quatre dimensions obtenue à partir d’une scanographie quadridimensionnelle sur laquelle nous avons appliqué un recalage élastique pour obtenir la dose cumulée.

Résultats

Notre étude montre que la dose cumulée (quadridimensionnelle) selon la position moyenne cycle respiratoire et le volume cible interne permet d’obtenir une distribution de dose identique dans le volume tumoral macroscopique, avec toutefois une meilleure épargne du poumon sain pour le modèle « position moyenne du cycle respiratoire » comparativement au modèle « volume cible interne ». Cette amélioration de l’indice thérapeutique permet, à partir d’une projection sur la dose maximale théorique dans le volume cible prévisionnel (respect strict des contraintes de dose aux poumons et à la moelle), un gain d’environ 11 % sur la dose totale (dose maximale de 86Gy pour le volume cible interne et 96Gy pour la position moyenne du cycle respiratoire).

Conclusion

Notre étude, reposant certes sur l’étude d’un cas de patient, confirme l’intérêt de la planification dosimétrique des tumeurs pulmonaires à partir de la position moyenne du cycle respiratoire.

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose

The dose distribution for lung tumour is estimated using a 3D-CT scan, and since a person breathes while the images are captured, the dose distribution doesn’t reflect the reality. A 4D-CT scan integrates the motion of the tumour during breathing and, therefore, provides us with important information regarding tumour’s motion in all directions, the motion volume (ITV) and the time-weighted average position (MVP).

Patient and methods

Based on these two concepts, we have estimated, for a lung carcinoma case a 3D dose distribution from a 3D-CT scan, and a 4D dose distribution from a 4-D CT scan. To this, we have applied a non-rigid registration to estimate the cumulative dose.

Results

Our study shows that the 4D dose estimation of the GTV is almost the same when made using MVP and ITV concepts, but sparring of the healthy lung is better done using the MPV model (MVP), as compared to the ITV model. This improvement of the therapeutic index allows, from a projection on the theoretical maximal dose to PTV (strictly restricted to doses for the lungs and the spinal cord), for an increase of about 11% on the total dose (maximal dose of 86Gy for the ITV and 96Gy for the MVP).

Conclusion

Further studies with more patients are needed to confirm our data.

Le texte complet de cet article est disponible en PDF.

Mots clés : Volume cible interne, Position moyenne du cycle respiratoire, Dosimétrie quadridimensionnelle, Recalage élastique

Keywords : Internal target volume, Mid-ventilation position, 4D dose distribution, Non rigid registration


Plan


© 2011  Société française de radiothérapie oncologique (SFRO). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 16 - N° 2

P. 91-99 - avril 2012 Retour au numéro
Article précédent Article précédent
  • Optimisation de la radiothérapie involved-node grâce à l’inspiration profonde bloquée dans la maladie de Hodgkin
  • A. Paumier, M. Bakkour, M. Ghalibafian, A. Beaudre, P. Blanchard, F. Martinetti, T. Girinsky
| Article suivant Article suivant
  • Évaluation de l’apport d’une méthode standardisée dans la définition du lit tumoral à l’aide de clips chirurgicaux dans le cancer du sein
  • S. Thureau, S. Oden, R. Mokaouim, S. Mezzani-Saillard, F. Clatot, C. Hanzen

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.