S'abonner

Comparaison dosimétrique des radiothérapies conformationnelles avec modulation d’intensité par faisceaux statiques et RapidArc® des cancers du col - 27/06/12

Doi : 10.1016/j.canrad.2012.02.002 
S. Renard-Oldrini a, , C. Brunaud a, S. Huger b, V. Marchesi b, L. Tournier-Rangeard a, D. Bouzid b, V. Harter c, D. Peiffert a
a Département de radiothérapie, centre Alexis-Vautrin, avenue de Bourgogne, 54511 Vandœuvre-lès-Nancy cedex, France 
b Unité de physique médicale, centre Alexis-Vautrin, avenue de Bourgogne, 54511 Vandœuvre-lès-Nancy cedex, France 
c Département d’information médicale, centre Alexis-Vautrin, avenue de Bourgogne, 54511 Vandœuvre-lès-Nancy cedex, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 6
Iconographies 3
Vidéos 0
Autres 0

Résumé

Objectif de l’étude

La chimioradiothérapie complétée par une curiethérapie est le traitement standard des cancers du col utérin localement évolués. La radiothérapie est responsable de toxicité digestive et hématologique, majorée par la chimiothérapie. L’utilisation de la radiothérapie conformationnelle avec modulation d’intensité (RCMI) par des faisceaux statiques permet une diminution de cette toxicité. La technique de RCMI RapidArc® pourrait améliorer l’épargne des organes à risque et l’homogénéité du volume-cible prévisionnel, tout en diminuant le temps de traitement.

Patientes et méthode

L’objectif de l’étude est la comparaison des plans de traitement de 20 patientes, simulés en RCMI par faisceaux fixes et RapidArc®. Les volumes cibles étaient le volume-cible anatomoclinique (volume tumoral macroscopique, utérus, tiers supérieur du vagin, aires ganglionnaires obturatrices, iliaques et présacrées), et le volume-cible prévisionnel (volume-cible anatomoclinique+1cm). Les organes à risque délinéés étaient le rectum, la vessie, l’intestin et la moelle osseuse. La dose prescrite était de 45Gy en 25 fractions. La RCMI classique a été délivrée par cinq faisceaux fixes et la RCMI RapidArc® par deux arcs. Les comparaisons ont été effectuées par le test non paramétrique de Wilcoxon.

Résultats

La couverture moyenne du volume-cible prévisionnel était supérieure avec la RCMI RapidArc® (p=0,01). Elle permettait une meilleure épargne intestinale (p=0,01) et la RCMI par faisceaux fixes, une meilleure épargne vésicale (p=0,01) et rectale (p=0,05). Le volume total recevant 20Gy était moins grand avec la RCMI RapidArc® (p<0,001). Le RCMI RapidArc® permettait de diminuer le temps de traitement (trois contre 12minutes avec les faisceaux fixes) et le nombre d’unités moniteur (UM) (376,5 contre 962,2 en moyenne, p=0,0001).

Conclusion

La technique de RCMI RapidArc® semble apporter des résultats dosimétriques supérieurs à ceux de la RCMI par faisceaux fixes, avec moins d’UM et temps de traitement plus court.

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose

Concurrent radiochemotherapy is the standard treatment for locally advanced cervical cancer. This treatment is responsible for bowel and hematologic toxicities. The use of intensity-modulated radiotherapy (IMRT), in static beams, allows a decrease of this toxicity. The technique of RapidArc® IMRT could lower the dose delivered to the organs at risk and improve the homogeneity of the planning target volume coverage, while decreasing the processing time.

Patients and materials

For 20 patients, treatment plans performed with IMRT and RapidArc® were compared. The target volumes were: the clinical target volume (gross tumour volume, uterus, upper third of the vagina, the hypogastric, iliac and presacral nodal regions), and the planning target volume (clinical target volume+1cm). The delineated organs at risk were: rectum, bladder, bowel and bone marrow. The dose was 45Gy in 25 fractions. IMRT were delivered with five beams and RapidArc® with two arcs. The comparisons were made by the non-parametric test of Wilcoxon.

Results

Medium coverage of the planning target volume was better with RapidArc® (P=0.01). It was also better regarding the sparing of bowel (P=0.01) and IMRT was better regarding the sparing of bladder (P=0.01) and rectum (P=0.05). The total volume receiving 20Gy was less important with RapidArc® (P<0.001). RapidArc® allowed to decrease the treatment time (3 versus 12minutes with IMRT) and the number of monitor units (MU) (376.5 versus 962.2, on average, P=0.0001).

Conclusion

The technique of RapidArc® seems to obtain better dosimetric results compared to RCMI, with fewer MU, and a significant decrease in treatment time.

Le texte complet de cet article est disponible en PDF.

Mots clés : Cancer du col utérin, Radiothérapie conformationnelle avec modulation d’intensité

Keywords : Cervix cancer, Intensity-modulated radiotherapy


Plan


© 2012  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 16 - N° 3

P. 209-214 - mai 2012 Retour au numéro
Article précédent Article précédent
  • Méthode Orion® : analyse systémique simple et efficace des événements cliniques et des précurseurs survenant en pratique médicale hospitalière
  • F. Debouck, É. Rieger, H. Petit, G. Noël, L. Ravinet
| Article suivant Article suivant
  • Réflexion éthique sur la pluridisciplinarité et la confidentialité de l’information en imagerie médicale via les nouvelles technologies de l’information et la communication
  • J. Béranger, P. Le Coz

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.