S'abonner

Reliability of a new method for lower-extremity measurements based on stereoradiographic three-dimensional reconstruction - 02/08/12

Doi : 10.1016/j.otsr.2012.03.014 
B. Guenoun a, , F. Zadegan b, F. Aim b, D. Hannouche b, R. Nizard b
a Department of Orthopedic and traumatology Surgery “A”, Cochin, Port-Royal Hospital Group (AP–HP), 27, rue du Faubourg-Saint-Jacques, 75679 Paris, France 
b Department of Orthopedic and traumatology Surgery, Lariboisiere, Fernand-Widal-Saint Louis Hospital Group (AP–HP), 2, rue Ambroisé-Paré, 75475 Paris cedex 10, France 

Corresponding author. Tel.: +33 1 58 41 30 82; fax: +33 1 58 41 30 87.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Thursday 02 August 2012
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Summary

Introduction

Several clinical and radiological techniques have been described to assess lower limb length and angle measurements. None of them has yet met the ideal criteria for a reliable, reproducible, safe, and inexpensive system. In this context, a new biplanar X-ray system (EOS™, EOS imaging, Paris, France) makes it possible to obtain a 3D reconstruction of the lower extremities from two 2D orthogonal radiographic images, with associated calculation of 3D measurements. The reliability of this technique has never been documented on adults.

Hypothesis

Lower limb measurements produced by the 3D EOS™ reconstruction system are reproducible regarding inter- and intraobserver assessment and more reliable with this 3D technique than when they are obtained from 2D measurements.

Materials and methods

This study included 25 patients awaiting total hip arthroplasty (50 lower limbs). Two independent observers made all measurements twice, both on the 2D frontal radiograph and using 3D reconstructions (femoral measurements of length, offset, neck shaft angle, neck length, and head diameter, as well as the tibia length, limb length, HKA and HKS). Reproducibility was estimated by intraclass correlation coefficients.

Results

Both the inter- and intraobserver reproducibility of the EOS™ measurements was excellent; more specifically inter- and intraobserver reproducibility was 0.997 and 0.997 for femoral length, 0.996 and 0.995 for tibial length, 0.999 and 0.999 for limb length, 0.894 and 0.891 for HKS, 0.993 and 0.994 for HKA, 0.870 and 0.845 for femoral offset, and 0.765 and 0.851 for neck shaft angle. For most of the variables, the interobserver correlations were statistically better with the EOS™ 3D reconstruction.

Discussion

Our results show that the EOS™ systems allow reproducible lower limb measurements. Furthermore, 3D EOS™ reconstructions offer better reproducible measures for most of the parameters than radiographic 2D projection. Its use before deciding on surgery and during planning for lower limb arthroplasty appears essential to us.

Level of evidence

Level III: diagnostic prospective study on consecutive patients.

Le texte complet de cet article est disponible en PDF.

Keywords : Radiographic image interpretation, Computer-assisted orthopaedics, Skeletal imaging, Three-dimensional, Radiation dosage, Leg length measurements


Plan


© 2012  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.