S'abonner

Expérience multicentrique de l’utilisation du Sheathless 6.5 French dans l’angioplastie coronaire des lésions de bifurcation : faisabilité et sécurité - 13/11/12

Doi : 10.1016/j.ancard.2012.09.012 
R. Cheaito a, H. Benamer a, , b , A. Tritar a, H. Mustafic a, Y. Derraz a, O. Tavolaro b, c, T. Hovasse a, b, C. Gaultier a, P. Garot b, c, T. Lefevre b, Y. Louvard a, b, M.-C. Morice b
a Service de cardiologie, European hospital of Paris (HEP) La Roseraie, 120, avenue de la République, 93300 Aubervilliers, France 
b Service de cardiologie, hôpital Jacques-Cartier, 91300 Massy, France 
c Service de cardiologie, hôpital Claude-Galien, 91480 Quincy-sous-Sénart, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 8
Iconographies 2
Vidéos 0
Autres 0

Résumé

Contexte

L’angioplastie coronaire par voie transradiale augmente en fréquence et est associée à une réduction des complications vasculaires au site de ponction. Toutefois, la petite taille de l’artère radiale est une limitation majeure de cette technique, en particulier pour traiter les lésions de bifurcation qui nécessitent au moins un cathéter guide 6 French. Un cathéter guide Sheathless a récemment été mis en place et présente une large lumière interne pour un diamètre externe réduit.

Objectifs

L’objectif de cette étude est de rapporter notre expérience préliminaire concernant les interventions transradiales dans les lésions de bifurcation en utilisant un cathéter guide Sheathless de 6.5 French.

Patients et méthodes

De mars 2009 à février 2012, dans trois hôpitaux, 46 patients consécutifs ont eu une angioplastie coronaire par voie transradiale en utilisant le système de cathéter guide 6.5 French de type « Sheathless Eaucath® » en raison d’importants frottements liés à la petite taille de l’artère radiale.

Résultats

Dans cette étude, 46 patients ont été inclus avec un âge moyen de 72,13±16,41ans. La majorité des patients était des femmes avec un sex-ratio de 0,53. Le taux de réussite des procédures utilisant un système de cathéter guide de 6.5 French était de 100 %, sans aucun cas nécessitant une conversion vers un cathéter guide classique. Durant les procédures, les dispositifs supplémentaires utilisés dans cette cohorte comprenaient l’intravascular ultrasound (IVUS) chez deux patients, un patient a nécessité une athérectomie rotationnelle, un cathéter de thromboaspiration a été utilisé chez quatre patients et une angiographie guidée par fractional flow reserve (FFR) a été réalisée chez quatre patients, enfin 35 lésions ont été traitées avec la technique de kissing-balloon. Nous rapportons aussi un cas d’occlusion chronique totale de lésion bifurquée traité avec succès en utilisant ce cathéter hydrophile. Il n’y a pas eu de complication au site de ponction de l’artère radiale.

Conclusion

Le traitement des lésions de bifurcation coronaire avec un cathéter guide Sheathless de 6.5 French par voie radiale est une procédure réalisable avec succès et qui semble sûre.

Le texte complet de cet article est disponible en PDF.

Abstract

Background

Transradial intervention of coronary lesion is increasing in frequency and is associated with lower major vascular access site complications. However, the small size of the radial artery is a major limitation of this technique, especially for bifurcation lesions, because 6-French guiding catheters are necessary to optimize the technique. A Sheathless guiding catheter has recently been introduced, optimizing a large lumen with a small size.

Objectives

The aim of this study is to report our preliminary experience performing bifurcated transradial interventions using a 6.5 French Sheathless guide catheter.

Patients and methods

From March 2009 to February 2012 in three hospitals, 46 consecutive patients were enrolled in this study who underwent transradial approach (TRA) for percutaneous bifurcation coronary interventions using the 6.5 French Sheathless Eaucath guiding catheter system because of small radial artery caliber.

Results

In this study, 46 patients were enrolled with mean age of 72.13±16.41 years. The majority of patients were females with sex-ratio 0.53. Procedural success using the 6.5 French Sheathless guide catheter system was 100 % with no cases requiring conversion to a conventional guide and catheter system. During procedures, adjunctive devices used in this cohort included IVUS (2 patients), 35 bifurcated lesions were treated with a kissing-balloon technique in the group of 46 patients undergoing bifurcation PCIs, one patient required rotational atherectomy, thrombus-aspiration catheters had used in four patients, FFR-guided angiography in four patients. We report one case of chronic total occlusion bifurcated lesion successfully treated using this hydrophilic catheter. There were no radial artery site complications.

Conclusion

The treatment of coronary bifurcation lesions with 6.5 French Sheathless guiding catheter by transradial approach is feasible and appears safe in this multicenter study.

Le texte complet de cet article est disponible en PDF.

Mots clés : Abord transradial, Angioplastie coronaire, Lésion de bifurcation coronaire, Petites artères radiales, Cathéter guide Sheathless

Keywords : Transradial approach, PCI, Bifurcation coronary lesion, Small radial arteries, Sheathless guiding catheter


Plan


© 2012  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 61 - N° 6

P. 405-412 - décembre 2012 Retour au numéro
Article précédent Article précédent
  • Le plus difficile est de dire non
  • H. Benamer, B. Livarek, J. Monségu
| Article suivant Article suivant
  • Utilisation des ballons actifs dans l’angioplastie coronaire : indications actuelles et perspectives
  • M. Angioi

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.