Quality and reproducibility of French publications on total hip arthroplasty - 19/04/13

Doi : 10.1016/j.otsr.2013.02.001 
C. Delaunay a, , L. Iovanescu b, L. Necas c, R. Hochgatterer d, G. Labek e

the Quality of Literature in Arthroplasty study group of the European Arthroplasty Register

a Clinique de l’Yvette, 67, route de Corbeil, 91160 Longjumeau, France 
b Orthopedic Surgery Department, Vasile Goldiş Western University of Arad, 1 Victoriei, 310031 Arad, Romania 
c Orthopedic Surgery Department Kollárova 2, University of Martin, 036 59 Martin, Slovakia 
d Orthopedic Surgery Department, Linz General Hospital, Krankenhausstrasse 9, A-4020 Linz, Austria 
e Orthopedic Surgery Department, University of Innsbruck, Anichstrasse 35, A-6020 Innsbruck, Austria 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Introduction

The goal of the Quality of Literature in Arthroplasty (QoLA) project launched in 2009 was to compare the implant results from clinical studies published in indexed scientific journals with those found in reference national registers. The potential biases in the chosen articles (country of origin, inventor involved in study, methodological quality) were systematically analyzed and the revisions per 100 observed component years (Revp100OCY) index was calculated. For a given implant, a differential factor greater than 3 between the Revp100OCY index for published series and the one from registers was considered as indicative of a potential selection (inventor) or publication (conflict of interest) bias. Although initially performed on English publications, this methodology was subsequently applied to French publications in the field of total hip arthroplasty (THA).

Material and methods

French publications indexed in Medline (Rev Chir Orthop and Orthop Trauma Surg Res since 2009) were analyzed. These studies involved implants designed in France (ABG™, Corail™ stem, Cerafit™/Osteal™, Bousquet) or that were used worldwide (Omnifit™ stem, Alloclassic™ and Charnley-type or Müller-type implants). The articles or abstracts selected had to contain sufficient information (number of revisions, number of cases and/or revisions, average follow-up) to allow the Revp100OCY index to be calculated.

Results

Overall, the average Revp100OCY index for THA series published in French was 0.76, which is consistent with the worldwide average of 1.29. For the ABG™ System, the Revp100OCY index was 1.5, which was higher than register data (0.77). Cemented Charnley-type stems had a Revp100OCY index of 1.68 (register 0.64) and low friction arthroplasty type THA had a Revp100OCY index of 0.59 (register 0.33). The Revp100OCY index was slightly lower relative to register data for the Müller THA (0.22 versus 0.33), Corail™ stem (0.1 versus 0.24), Omnifit™ (0.26 versus 0.37) and Alloclassic™ (0.21 versus 0.49). Other implants without comparable register data had a relatively high Revp100OCY index: 1.2 for the Bousquet dual mobility cup and 1.35 for the Osteal™/Cerafit™ hybrid system.

Conclusions

The few studies published in French include only a limited number of cases, but their follow-up is long and the revision rate consistent with register data. There is no indication of any type of bias in French scientific publications relative to the reproducibility of THA results.

Le texte complet de cet article est disponible en PDF.

Keywords : Prosthetic implants, Total hip arthroplasty, Scientific, Medical publication


Plan


© 2013  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 99 - N° 3

P. 257-262 - mai 2013 Retour au numéro
Article précédent Article précédent
  • Contents
| Article suivant Article suivant
  • European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing
  • F. Hannemann, A. Hartmann, J. Schmitt, J. Lützner, A. Seidler, P. Campbell, C.P. Delaunay, H. Drexler, H.B. Ettema, E. García-Cimbrelo, H. Huberti, K. Knahr, J. Kunze, D.J. Langton, W. Lauer, I. Learmonth, C.H. Lohmann, M. Morlock, M.A. Wimmer, L. Zagra, K.P. Günther

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.