S'abonner

Retinal Thickness and Volume Measured With Enhanced Depth Imaging Optical Coherence Tomography - 15/08/13

Doi : 10.1016/j.ajo.2013.04.027 
Sung Yong Park a, Sung Min Kim a, Yun-Mi Song b, Joohon Sung c, d, Don-Il Ham a,
a Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea 
b Department of Family Medicine, Samsung Medical Center, and Center for Clinical Research, Samsung Biomedical Research Institute, Sungkyunkwan University School of Medicine, Seoul, South Korea 
c Department of Epidemiology and Institute of Environment and Health, School of Public Health, Seoul National University, Seoul, South Korea 
d Genomic Medicine Institute, Medical Research Center, Seoul National University, Seoul, South Korea 

Inquiries to Don-Il Ham, Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, Seoul 135-710, South Korea

Abstract

Purpose

To evaluate the retinal thickness and volume measured with the enhanced depth imaging (EDI) method compared with those measured with the conventional method using spectral-domain optical coherence tomography (OCT).

Design

Retrospective, observational, case-control study.

Methods

Clinical records of 20 healthy subjects and those of 35 patients with chorioretinopathy (central serous chorioretinopathy, polypoidal choroidal vasculopathy, Vogt-Koyanagi-Harada disease, and reticular pseudodrusen) were analyzed retrospectively. All subjects underwent spectral-domain OCT using both the conventional and the EDI OCT raster scan protocols. The raster scan was composed of 31 B-scans that were 9.0 mm in length and 240 μm apart. Retinal thickness and volume of 9 Early Treatment Diabetic Retinopathy Study subfields were investigated. Intraclass correlation coefficients, Bland-Altman plots, and Wilcoxon signed-rank test results were used for the analysis.

Results

Sixty-five eyes of 35 patients with chorioretinal diseases and 40 eyes of 20 normal healthy subjects were evaluated. The automatically measured retinal thickness and volume of 9 Early Treatment Diabetic Retinopathy Study subfields with conventional and EDI raster scan showed an intraclass correlation coefficient of 0.861 to 0.995 and 0.873 to 0.995, respectively. The 95% limits of agreement between the 2 protocols in the measurement of central subfield were −14.52 to 12.88 μm in retinal thickness and −0.014 to 0.013 mm3 in retinal volume. The differences of segmentation error rate between the 2 protocols were statistically insignificant (P > .05), except in eyes with reticular pseudodrusen in the subgroup analysis (P = .006). No significant differences were observed in measured values between healthy eyes and unaffected fellow eyes.

Conclusions

The EDI OCT raster scan showed high agreement with conventional OCT in the measurement of retinal thickness and volume and could be used to evaluate both the retina and choroid in normal eyes and in eyes with some forms of chorioretinal disorder.

Le texte complet de cet article est disponible en PDF.

Plan


© 2013  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 156 - N° 3

P. 557 - septembre 2013 Retour au numéro
Article précédent Article précédent
  • The Phillips Thygeson Experiment in Trachoma
| Article suivant Article suivant
  • Diagnostic Precision of Retinal Nerve Fiber Layer and Macular Thickness Asymmetry Parameters for Identifying Early Primary Open-Angle Glaucoma
  • Michael Sullivan-Mee, Claudia C. Ruegg, Denise Pensyl, Kathy Halverson, Clifford Qualls

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.