Background

Distal femur torsion (DFT) is a crucial parameter in knee replacement surgery. The reference standard for measuring DFT is posterior condylar angle (PCA) measurement using computed tomography (CT). The objective of this study was to assess the feasibility and reliability of a radiographic PCA measurement method.

Materials and methods

We studied 125 osteoarthritic knees in 79 patients (42 women and 37 men) with a mean age of 71.6±8.8years (range 47 to 86 years); 32 knees were aligned, 85 in varus, and eight in valgus. DFT was measured on an antero-posterior (AP) radiograph of the knee in 90° of flexion (known as the seated AP view). The PCA was defined as the angle subtended by the tangent to the posterior condyles and the transepicondylar axis (anatomic PCA [aPCA]) or the line connecting the lateral epicondyle to the medial sulcus (surgical PCA [sPCA]). The PCA was conventionally recorded as positive in the event of external torsion and negative in the event of internal torsion. PCA measurements were performed three times by each of five observers to allow assessments of inter-observer and test-retest reliabilities.

Results

aPCA was consistently negative (mean, −6.1±1.6°) (range, 0 to −10°); inter-observer and test-retest reliability were satisfactory (0.54<rw0.80). sPCA was positive in 41 knees and negative in 84 knees) (mean, −0.3±1.4°) (range, −5° to +2°); inter-observer and test-retest reliabilities were poor (0.28<r<0.69). A weak but significant correlation was found between aPCA and coronal alignment, with a trend towards greater internal torsion in the group of valgus knees.

Conclusion

Radiographic measurement of DFT is simple and non-invasive. Measurement reproducibility was satisfactory for aPCA but not for sPCA. aPCA showed marked inter-individual variability and tended to increase when the knee was in valgus. Mean aPCA values were comparable to those reported using CT. In contrast to CT, radiographic DFT measurement can easily be incorporated into the pre- and postoperative work-ups for knee replacement surgery, provided the patient can achieve 90° of knee flexion.

Level of evidence

Level IV, prospective cohort study.

Le texte complet de cet article est disponible en PDF.

Keywords : Total knee arthroplasty, Distal femoral torsion, Transepicondylar axis, Posterior condylar angle, Conventional radiography, Seated radiography


Plan


© 2013  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 99 - N° 5

P. 517-522 - septembre 2013 Retour au numéro
Article précédent Article précédent
  • Measuring femoral and rotational alignment: EOS system versus computed tomography
  • D. Folinais, P. Thelen, C. Delin, C. Radier, Y. Catonne, J.Y. Lazennec
| Article suivant Article suivant
  • Subchondral cyst development and MMP-1 expression during progression of osteoarthritis: An immunohistochemical study
  • A. Kaspiris, L. Khaldi, T.B. Grivas, E. Vasiliadis, I. Kouvaras, S. Dagkas, E. Chronopoulos, E. Papadimitriou

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.