Résumé

Introduction

Over the last decades, the possibilities for monitoring the presence of drugs of abuse in oral fluid (OF) has increased enormously. Especially in the domain of testing drivers under influence of drugs (DUID), OF has gained popularity due to its non-invasive collected, directly on-site without hampering privacy. Several on-site immunosorbent tests (OIT) were developed over the years. For confirmatory analysis, the use of OF has been hampered by the influence of the salivary composition on the final drug concentrations. The OF collection protocol, the degree of stimulation of salivary flow, the physicochemical properties of drugs of abuse, and the type of drug administration are some of the parameters that influence the OF drug concentrations. Moreover, the final analytical result will be influenced by the OF collection. As a result, toxicological analysis of OF samples and the final interpretation is not always straightforward.

Methods

Laboratory and roadside studies, as well as double-blind placebo-controlled studies are used to evaluate the problems encountered using OF as confirmation matrix. The focus is put on Δ9-tetrahydrocannabinol (THC) analysis. The placebo-controlled study involves 10 test subjects smoking two subsequent doses of THC; 300μg/kg and 150μg/kg with a pause of 75 minutes using a Volcano vaporizer. Using the above mentioned studies, OIT (Drug-Test®, Drager and Drugwipe®, Securetec) and several OF collection devices (StatSure®, Diagnostic Systems Inc; Quantisal®, Immunalysis and Certus®, Concateno) will be evaluated via UPLC-MS/MS analysis.

Results

Sensitivity of OIT seem to increase. The DrugTest 5000 and Drugwipe demonstrated respectively a sensitivity of 93% and 72% for Δ9-tetrahydrocannabinol during roadside studies. The Drugwipe is very sensitive just after smoking, but it rapidly decreases within 1.5 hours.

The type of OF collection has to be specified when using OF as confirmation matrix, as THC recovery ranged from 50 to 70% and is dependent on the storage conditions. While matrix effects due to the collector buffers are observed, stability is often guaranteed via the stabilizing buffers. In a roadside study, we observed that after 5 minutes collection time, about 0.11–1.15mL of OF was collected. Therefore, the final drug concentrations in neat OF have to be calculated via the following formula: C = [CUPLC/MS · (V1 + (W1–W2))] / [V2 x (W1–W2)] with C being the drug concentration in neat OF, CUPLC/MS the concentration obtained via the calibration curve, V1 the buffer volume, V2 the theoretical total collected volume and W1 and W2 respectively the weight of the collection device after and before OF collection. Neat OF THC concentrations in the placebo controlled study ranged from 12,361ng/g 5 minutes after smoking down to 34ng/g 80 minutes after 2 smoking sessions. Under placebo conditions, a median of 8ng/g THC in OF was observed. The impact of all these observations on DUID legislations will be discussed.

Conclusion

OF has its limitations as a toxicological matrix. However, in situations where ‘recent’ drug use in combination with analytical cut-offs for interpretations are used, OF combines an easy collection of samples with a quick analysis of large batches.

Le texte complet de cet article est disponible en PDF.

Plan

Plan indisponible

© 2014  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 26 - N° 2S

P. S1-S2 - juin 2014 Retour au numéro
Article précédent Article précédent
  • W1: Overview of oral fluid as toxicological matrix
  • A. Verstraete
| Article suivant Article suivant
  • W3: The French experience of establishing an oral fluid roadside drug test
  • O. Roussel, M. Perrin-Rosset, C. Fuché, M. Carlin

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.