O25: HPLC-HRMS vs UPLC-MS/MS for a systematic toxicological screening in hair - 28/06/14

Doi : 10.1016/S2352-0078(14)70033-2 
S. Vogliardi 1, M. Tucci 1, A. Nalesso 1, G. Stocchero 2, S.D. Ferrara 1, 2, D. Favretto 1, 2
1 Department of cardiac, thoracic and vascular sciences and public health, university of Padova, Padova, Italy 
2 Forensic toxicology and antidoping, university hospital, Padova, Italy 

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 2
Iconographies 0
Vidéos 0
Autres 0

Résumé

Aims

The aim of the present work was to compare the performances of HPLC-High Resolution Mass Spectrometry (HPLC-HRMS) in full scan and UPLC- Multiple mass spectrometry (UPLC-MS/MS) in multiple reaction monitoring (MRM) mode for the systematic, general unknown screening of drugs and pharmaceuticals in hair samples collected for clinical toxicology purposes at the local University Hospital.

Methods

10mg hair were washed and extracted by a rapid, micropulverized method already published. Extracts were analyzed in two different instruments, the former consisting of an Orbitrap coupled to a Finnigan Surveyor HPLC, the latter of a Xevo TQD triple quadrupole coupled to an Acquity UPLC. For HPLC, an Atlantis T3 (150 × 2,1mm, 3μm) was used while the UPLC employed a HSS C18 (150 × 2.1 × 1,8μm), with a gradient of ammonium acetate and acetonitrile (formic acid 0.1%) at 300μL/min and 400μL/min respectively. The Orbitrap was operated in positive ion electrospray mode at a resolution of 60000 with mass locking, in full scan mode, with a in-house developed library of 600 compounds; the identificatiion criteria were 2ppm accuracy of the exact mass of the protonated molecule, ± 0.1min of the retention time, a minimum area count of 10000 arbitrary units; the Xevo TQD worked in switching ion polarity electrospray mode, and in MRM using a Waters toxicology library of 800 (untargeted screening) or 180 compounds (targeted screening), a recognition window of ±0.2min and a minimum area count of 600 arbitraty units.

Results

Compounds belonging to drugs of abuse and/or to pharmaceutical drugs could be identified with both analytical approaches in the same hair samples. In more than 100 hair samples collected in the clinical settings in a year, drugs belonging to the following therapeutic categories were identified: anaesthetics, anti-epileptics, antidepressants, benzodiazepines, sedatives, hypnotics, opioids, anti-psychotics, neuroleptics, barbiturates, stimulants, non steroidal analgesics, steroids, beta-blockers, diuretics, antibiotics, antiarrhythmic agents, antihypertensive drugs, anti-coagulants, hypoglycaemic agents. The screening results were in every case confirmed by injection of the tentatively identified analyte(s) in methanol standard mixtures. When possible, the compliance with prescribed therapies or alleged use/abuse was verified.

Conclusions

The UPLC-MRM method turned to be more rapid than the HPLC-HRMS (14min vs 30min total run time); the possibility of polarity switching could be applied in routine only in the Xevo TQD allowing to easily identify acidic drugs such as non steroidal analgesics. The HPLC-Orbitrap, working in full scan, resulted superior for implementing the library with new molecules, since no adjustment of the acquisition method was needed, and for the postacquisition, retrospective screening of the raw files. In the UPLCMRM method, limits of identification with targeted analytes were in the order 0.1 – 0.2ng/mg for basic drugs, with 10mg hair samples, whereas in the HPLC-HRMS limits were generally lower.

Le texte complet de cet article est disponible en PDF.

Plan

Plan indisponible

© 2014  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 26 - N° 2S

P. S15-S16 - juin 2014 Retour au numéro
Article précédent Article précédent
  • O24: Supported ionic liquids towards contactless hair decontamination
  • J. Restolho, M. Barroso, B. Saramago, M. Dias, C. Afonso
| Article suivant Article suivant
  • O26: Validation of a GC-MS/MS method for the determination of cannabinoids in whole blood with respect to the requirements of the NF EN ISO 17025
  • F. Aknouche, E. Guibert, K. Fargeot, A. Tessier, P. Kintz

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.