The prognosis of total hip replacement in patients younger than 55 years of age. Results of 28,480 primary replacements from the Nordic Arthroplasty Register Association - 22/10/14

Doi : 10.1016/j.rcot.2014.09.183 
Søren Overgaard , Alma B. Pedersen, Frank Mehnert, Leif I. Havelin, Ove Furnes, Peter Herberts, Johan Kärrholm, Göran Garellick
 Department of Orthopaedic Surgery and Clinical Institute, Odense University Hospital, Odense, Denmark 

Corresponding author.

Résumé

Introduction

The aim of this study was to evaluate the patient and surgery related risk factors for revision following primary THR in patients younger than 55 years of age using the large population-based NARA dataset.

Materials and methods

Through the Nordic Arthroplasty Register Association (NARA) dataset we identified all primary THRs due to osteoarthritis in patients younger than 55 years of age performed in four Nordic countries from 1995–2011 (n=28,480). We estimated overall risk for revision due to any reason, due to aseptic loosening, and risk for any revision within 2 years. We used Cox regression analyses to calculated crude and adjusted Hazard ratio as a relative risk (RR) and 95% confidence interval (CI) in order to study patient and surgery related risk factors for revision.

Results

Overall revision risk following primary THR due to any cause was 7.9% (2240 out of 28,480 primary THR), whereas the revision risk due to aseptic loosening was 4.2% (1192 out of 28,480 primary THR). No difference in any revision risk regarding sex and age was evident, but female had lower risk of revision due to aseptic loosening (RR=0.86, 95% CI: 0.76–0.76). Uncemented implant had reduced risk for overall revision due to aseptic loosening (RR=0.52, 95% CI: 0.45–0.59), whereas hybrid implants had higher risk for overall any revision compared with cemented technique (RR=1.28, 95% CI: 1.13–1.45). However, overall differences were only observed during the period 1997-2003. Sex and age subgroup analyses reviled, that uncemented implants also had higher risk of any revision among females older than 45 years, whereas hybrid implants had particularly high risk for any revision among males older than 45 years.

Conclusion

Our large population-based study provides evidence that age, sex and calendar year of surgery were not risk factors for either overall any revision or revision due to aseptic loosening. In general, hybrid implant had higher risk for any revision, whereas uncemented implant had lower risk of revision due to aseptic loosening. However, the risk estimates for fixation technique were dependent on calendar year of surgery, as well as on age and gender.

Le texte complet de cet article est disponible en PDF.

Plan


© 2014  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 100 - N° 7S

P. S286 - novembre 2014 Retour au numéro
Article précédent Article précédent
  • Prothèse totale de hanche à double mobilité chez des sujets de moins de 50 ans – survie à 20 ans de recul
  • Brice Viard, Rémi Philippot, Thomas Neri, Frédéric Farizon
| Article suivant Article suivant
  • Analyse quantifiée de la station debout en fonction des trois principales voies d’abord de la hanche
  • Stéphane Van Driessche, Julien Beldame, Lucas Martinez, Fabien Billuart, Patrice Guiffault, Claude Weisang, Jean Matsoukis

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.