S'abonner

Predictive factors of scapular notching in patients with reverse shoulder arthroplasty - 29/10/14

Doi : 10.1016/j.otsr.2014.06.013 
N. Bigorre a, , R. Lancigu b, P. Bizot b, L. Hubert b
a Centre de la main, 47, rue de la Foucaudire, 49800 Trélazé, France 
b Département de chirurgie osseuse, 4, rue Larrey, 49933 Angers, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

The main complication of reverse shoulder arthroplasty is the development of notches in the scapular pillar, which occurs in 44% to 100% of cases. Furthermore the functional score has been shown to be poorer in patients with high-grade notches. Many options have been proposed to reduce this risk. The purpose of this study was to evaluate the predictive factors of the development of scapular notches.

Materials and methods

We retrospectively evaluated 133 shoulders in 121 patients with reverse shoulder arthroplasty. We performed a radiographic assessment of the effect of positioning the glenoid component with inferior overhang of the glenosphere and the glenometaphyseal angle. All patients were reviewed after 2years follow-up, including a clinical assessment based on the Constant score and X-rays to assess the presence of notches.

Results

Nineteen complications were reported, and 14 required revision surgery. We excluded patients in whom prosthetic components were changed. The quality of the X-rays was not satisfactory enough to be analyzed in over 15 patients so they were excluded. One hundred five patients were reviewed. At 2years follow-up, 50.4% of shoulders presented with notches. The Constant score was 69.3 points (54–83) in shoulders without notches, and 66.4 points (38–82) in shoulders with notches. The average glenosphere overhang was 3.5mm (−1 – 8mm). Notches were present in 65.5% if it was less than 3mm and 39.6% if it was more than 2mm (P<0. 05). The average glenometaphyseal angle was 27.3° (4–59°), and notches developed in 72.2% if it was more than 28° and 26.5% if it was less than 28° (P<0.05).

Conclusion

The position of the metaglene influences the development of notches. The risk decreases if the glenosphere overhangs the glenoid. The degree of adduction of the arm influences the development of notches and can be correlated with the patient's BMI.

Level of evidence

Level IV retrospective study.

Le texte complet de cet article est disponible en PDF.

Keywords : Reverse shoulder arthroplasty, Cuff tear arthropathy, Inferior scapular notching


Plan


© 2014  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 100 - N° 7

P. 711-714 - novembre 2014 Retour au numéro
Article précédent Article précédent
  • Outcomes of bipolar radial head prosthesis to treat complex radial head fractures in 22 patients with a mean follow-up of 50 months
  • C. Allavena, S. Delclaux, N. Bonnevialle, M. Rongières, P. Bonnevialle, P. Mansat
| Article suivant Article suivant
  • A patient-specific measurement technique to model shoulder joint kinematics
  • C. Charbonnier, S. Chagué, F.C. Kolo, J.C.K. Chow, A. Lädermann

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.