S'abonner

Can reverse shoulder arthroplasty in post-traumatic revision surgery restore the ability to perform activities of daily living? - 01/04/15

Doi : 10.1016/j.otsr.2014.12.007 
M.W. Maier a, , F. Zeifang a , M. Caspers a , T. Dreher a , M.C. Klotz a , O. Rettig a , S.I. Wolf a , P. Kasten b
a Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany 
b Orthopedic Surgery Center (OCC) Tübingen, University Department of Orthopedic Surgery, Hoppe-Seyler-Strasse, 3, 72076 Tübingen, Germany 

Corresponding author. Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstraβe, 200a, 69118 Heidelberg, Germany. Tel.: +49 6221 56 25000; fax: +49 6221 6347.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Failed shoulder arthroplasty and failed internal fixation in fractures of the proximal humerus can benefit from implantation of a reverse total shoulder arthroplasty (RSA). While there is some evidence that RSA can improve function regarding range of motion (ROM), pain, satisfaction, and strength, there is sparse data how this translates into activities of daily living (ADLs). A marker-based 3D video motion analysis system has recently been designed that can measure changes of ROM in dynamic movements in every plane. The hypothesis was that a gain of maximum ROM also translates into the ability to perform ADLs and into a significant increase of ROM in ADLs.

Materials and methods

Six consecutive patients (5 women, 1 man; 2× failed arthroplasty, 4× failed open reduction and internal fixation) who received RSA were examined the day before and 1 year after shoulder replacement. A 3D motion analysis system using a novel upper extremity model measured active maximum values and ROM in four ADLs.

Results

Comparing the pre- to the 1-year postoperative status, RSA resulted in a significant increase in mean maximum values for active flexion (humerus to thorax) of 37° (S.D. ±23°), from 50 to 87° [P=0.005], and for active abduction averaging of 17° (S.D. ±13°), from 52 to 69° [P=0.027]. The extension decreased significantly by about 8° (S.D. ±16°), from a mean of 39 to 31° [P=0.009]. For active adduction and internal and external rotation, there were trends for improvements, but no significant changes. Only three additional tasks of the ADL (out of 13/24 preoperatively) could be performed after revision surgery. Comparing the preoperative to the postoperative ROM in the ADLs in flexion/extension, ROM improved significantly in one (“tying an apron”) of four ADLs. There were no significant changes in the abduction/adduction and internal/external rotation in any ADLs.

Conclusion

RSA in revision cases significantly improved maximum active flexion and abduction, but decreased extension in this series. However, the patients were only able to use this greater ROM to their benefit in one of four ADLs.

Le texte complet de cet article est disponible en PDF.

Keywords : Reverse shoulder arthroplasty, Revision, Outcome, Failed arthroplasty, Failed osteosynthesis, Marker-based system, Upper extremity, Biomechanical model, Functional testing, Activity of daily living


Plan


© 2015  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 101 - N° 2

P. 191-196 - avril 2015 Retour au numéro
Article précédent Article précédent
  • Evaluation of a new baseplate in reverse total shoulder arthroplasty – comparison of biomechanical testing of stability with roentgenological follow up criteria
  • U. Irlenbusch, G. Kohut
| Article suivant Article suivant
  • Intrinsic and extrinsic risk factors for nonunion after nonoperative treatment of midshaft clavicle fractures
  • W. Liu, J. Xiao, F. Ji, Y. Xie, Y. Hao

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.